Motorola SE4710 Integration Manual page 61

Table of Contents

Advertisement

SE4710 Command and Response Formats (Continued)
Table 5-3
Function
MIRROR_AND_FLIP
IMAGER_INTERFACE_TYPE
ENTER_BOOTLOADER
DRIVE_STRENGTH
ILLUMINATION_POWER_LEVEL
AIM _POWER
Notes:
1. Every command has a 1 byte checksum (last byte of command). See Command Checksum on page 5-4.
2. Every response has a 1 byte status code immediately following the Opcode. See Response Status Code on page
5-4.
3. These commands/responses have a variable length data field indicated by (A):Array. See Table 5-4 on page 5-14
for the length of the field based on the param number.
SE4710 Command
SE4710 Command Data
Op
(see Note 1)
0x85
(B)
0x00 = Default Orientation*
0x01 = Mirror Only
0x02 = Flip Only
0x03 = Mirror and Flip
0x86
(B)
0x00 = No configuration*
0x03 = MIPI
0x04 = Parallel
0x91
(A) Signature (3 bytes:
0xAA, 0x50, 0x5F)
0x99
(B)
0x00 = Use Default Setting
0x01 = 1.8v Low
0x02 = 1.8v Med
0x03 = 1.8v High
0x04 = 3.3v Low
0x05 = 3.3v Med
0x06 = 3.3v High
0xF0
(B)
0x01 = Low
0x1B = High
0x07 = Default
0xF3
(B)
0x00 = Low
0x01 = Med
0x02 = High*
Control Interface 5 - 13
SE4710 Response
SE4710 Response Data
Op
(see Note 2)
0x85
-
0x86
-
0x91
-
0x99
-
0xF0
-
0xF3
-