GET_EXTENDED_STATUS 0x79

The SE4710 internally tracks various operating states and stores these states in the extended status structure.
This command gets these states from the SE4710. The following are the operating conditions and descriptions.
Each operating condition has 2 bits in the extended status:
Instantaneous bit - set if the condition exists when the GET_EXTENDED_STATUS command is issued. If the
condition occurred in the past and no longer exists, the bit is cleared. These bits are reported in the first byte
of the extended status data.
Latched bit - set when the condition is first detected and remains set (even if the condition no longer exists)
until the GET_EXTENDED_STATUS command is issued, which clears the bit. If a latched bit is set when the
GET_EXTENDED_STATUS command is issued, this indicates the condition occurred at some point since
the last GET_EXTENDED_STATUS command. These bits are reported in the second byte of the extended
status data.
Note that these conditions are bit positions within the extended status bytes; these conditions can occur
simultaneously resulting in values not shown below.
Operating States (Individual Bytes)
0x01:
0x02:
0x02, 0x04, 0x20, 0x40: Internal warning.

GET_FSTATS 0x81

When issued, the command returns a response containing information about the last captured frame. This
information includes the following: exposure (2 byte), gain (byte), bin (byte) and statistics (byte), where the
statistics byte is defined as follows:
0x01 = Illumination on
0x02 = Aim on
0x10 = Picklist frame
0x20 = LCD frame

GET_PARAM 0x70

Allows a host to read out parameters stored in the SE4710 (non-volatile memory). See
a list of these parameters.

ILLUMINATION_DURING_EXPOSURE 0x59

Turns Illumination on and off. Illumination only turns on if acquisition is started. Enabling illumination while
acquisition is stopped does not turn illumination on, although it turns on illumination upon the next ACQUISITION
Start command.
The internal temperature reached thermal warning at which time the aimer is
turned off, and the illumination dims.
The internal temperature reached thermal fatal at which time the illumination
turns off.