Specifications Of Electrical Parts - Toshiba RAS-4M27U2AVG-E Service Manual

Split type
Hide thumbs Also See for RAS-4M27U2AVG-E:
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

No.
Parts name
1
Compressor
2
Outdoor fan motor
3
Reactor
4
Reactor
5
4-way valve coil
6
PMV coil
7
P.C. board (Main PCB)
8
P.C. board (Control PCB)
9
P.C. board (Fan motor connection)
10
Fuse (Mounted on P.C. board MCC-1571)
11
Fuse (Mounted on P.C. board MCC-1571)
12
Fuse (Mounted on P.C. board MCC-1571, WP-041)
13
Outdoor temp. sensor (TO sensor)
14
Evaporator temp. sensor (TE sensor)
15
Discharge temp. sensor (TD sensor)
16
Suction temp. sensor (TS sensor)
17
Temp. sensor at A room gas side (TGa-sensor)
18
Temp. sensor at B room gas side (TGb-sensor)
19
Temp. sensor at C room gas side (TGc-sensor)
20
Temp. sensor at D room gas side (TGd-sensor)
21
Compressor thermo.
High-pressure SW
22
23
Terminal block (6P)
24
Terminal block (9P)
Model name
DX220A2T-20L
ICF-280-A60-1
CH-56-3Z-T
CH-76-2VK
STF-H01AP1874A1
UKV-A039
MCC-1571
WP-041
MCC-1436
CS-12AL
ACB-4UB83W
- 36 -
FILE NO. SVM-18052
Rating
3 Phases (4-Poles) ; 2000 W
Output 60 W
5.8 mH, 18.5 A
9.9 mH, 1 A
AC 200–240 V
DC 12 V
AC 220–240 V
AC 220–240 V
AC 220–240V
AC 250V, 25 A
AC 250V, 10 A
AC 250V, 3.15 A
10 kΩ (25°C)
10 kΩ (25°C)
50 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
10 kΩ (25°C)
ON: 90°C, OFF: 125°C
OFF : 4.15MPa
AC 250 V, 20 A
AC 250 V, 20 A

Hide quick links: