7.5.

Power Supply Unit Selection

The PBX needs a power supply unit (PSU) suitable for its configuration. Calculate the load figure from the type and number of
items of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
PT
Extension Card *1
CS (1 unit)
PT-interface CS (1 unit)
ISDN Extension
VPS (1 port)
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capacity
Each PSU supports a different load figure.
Equipment Type
KX-T7600 series DPT/KX-T7600 series DSS console
KX-T7560/KX-T7565 DPT
Other DPT/Other DSS console
APT
IP-PT
SIP Extension
DHLC8
SLC8
SLC16
MSLC16
PSU Type
PSU-L
PSU-M
Maximum Load Figure
512
128
32
Load Figure
1
1
4
4
0
0
8
8
16
16
4
4
2
1