7.
Install RF board into unit controller. Line up pins in RF board and press firmly into black connectors. Note ori-
entation of RF board (see Figure 12).Make sure the RF board is fully seated into all of the sockets. Reconnect
power.
8.
Follow the directions on the next page to program BOTH the main and remote monitor units to communicate
with each other. If modem has been installed in the remote, it is also necessary to follow the directions in the
next section of this manual to configure the main controller to use the modem in the remote.
Wireless Remote Setup
Begin the wireless setup using the wireless remote device.
RUNNING
JAN-01-12
12:01P
1) INFORMATION
>2) SETUP
3) DIAGNOSTICS
>1) RF SETUP
2) MODEM SETUP
Wireless Remote Settings
Screen Display
CHANNEL #
1
RF FREQUENCY
915 Mhz

Cat. No. 01023095

Figure 12.
RF board location on GROC board.
1.
From the default home screen, press
2.
Press
to select 2)SETUP.
3.
Press
to select 1)RF SETUP.
Range
1–254
Press
or
valve. The CHANNEL # for the RO controller must be the same as the CHAN-
NEL # for the Remote Display.
433, 869,
Use this setting to select the correct radio frequency. Do not change the RF fre-
or 915
quency for North America installations.
RF Board (note orientation)
. The screen displays the main menu.
Changing the Setting
and then
to select the channel number of the control
Accessories
29