Appendix F Programming Log

Use this section to record the program settings for this system. Circle or enter the observed value. Make additional copies
to keep on file near the installation and with your local Culligan dealer.
Program Date: ___________ Installer: _____________________________
Record GROC ESN: _______ Firmware Version: _____________________
Language
Language
English/French/
Italian/Spanish
Time and Date
Month
Day
Year
Clock Type
12 Hr/24 Hr
Hour
Minutes
Daylight Saving
Yes/No
Power On Mode
Power On Mode
Running/Standby
System Units
System Units
US Inch/Metric
Flush Modes
Startup Mode
Off/On
Flush Duration
Standby Mode
Off/On
Flush Duration
Flush Every
Time Trigger
Off/On
Flush Duration
Flush Every
Flow Trigger
Off/On
Flush Duration
Flush Every
Quality Flush
Off/On
Flush Duration
TDS Level
Permeate Flush
Off/On
Flush Duration
Culligan® Series M2 Reverse Osmosis
116
Accessories
Wireless Remote
Remote Display
Installed/Not Installed
Channel #
RF Frequency
915/869/433
Modem
Telephone
Installed/Not Installed
Modem
Modem
Landline/CellModem
Connection
Modem Location
In Main Control/
In Remote
Time Zone GMT
Call Frequency
Call Time
Data Phone #
Dealer ID
Flow Meters
Installed/Not Installed
FM1 K Factor
FM2 K Factor
Switch Inputs
Pressure Switch
Open/Closed
PW SW Delay
SV1 Delay
Pretreat Switch
Open/Closed
Float Switches
Open/Closed
FS Hi Delay
Pressure Gauges
PG Install
Press Gauges
Yes/No
Calibrate PG1
Yes/No
PG1 Offset
PG1 Cal Factor
Calibrate PG2
Yes/No
PG2 Offset
PG2 Cal Factor
TDS
TDS Probe
None/Product/Both
Actual TDS In
Actual TDS Out
Temp Offset
Temp Comp
Value
Relay Mode
Off/Error Status/
Network
Flow Trigger
Site Location: ____________________
Accessories, cont.
Mult Unit RO
Single/Two-Pass RO/
Multi Unit RO
Role
Two Pass Delay
SV3
Set SV3 Mode
TDS Target
Value
TDS Target
Time
Error Limits
Max Pressure Diff
Min Rejection %
Max Recovery %
Min Recovery %
Max In Temp
Min In Temp
Max Feed Pressure
Min Feed Pressure
Max TDS Out
Max Pump Time
Min Normalized Flow
Std Pressure
On Remote Display
RF Setup
Channel #
Radio Frequency
Telephone Modem
Not Installed/Installed
Call Frequency
G2/G3
Only
Data Phone #
Pulsed
Output
Only
116
Alternating
Master/Slave
2-Pass
Master
Only
Flush Modes/
TDS Target
TDS
Target
Only
TDS
Target
Only
°F/°C
°F/°C
915/869/433
Daily/On Error/
Daily&Error/
Monthly&Error
Cat. No. 01023095