11. Technical data

Indication range:
Reaction time:
Indication:
Bar diagram;
Display size approx. 20 x 7 mm
1 bar = no concentration
14 bar = max. concentration
The ecom-LSG serves for
measurements are not possible!
Power supply:
Batteries 2 x 1,5 V AAA (micro) or
accu 2 x 1,2 V AAA NiCd (Nickel-Cadmium) or
accu 2 x 1,2 V AAA NiMh (Nickel-Metallhydride)
Warm-up time:
Operation temperature:
Storage temperature:
Operation moisture:
Changes in air humidity cause
indicator falsifications!
Dimensions:
- Housing:
- Swan-neck:
Weight:

12. Maintenance tip

To secure the accuracy of your measuring instrument we recommend the annual
check by an authorized ecom partner. In the case of strong demand (e.g. perma-
nent several hours of measurement per day, rough conditions etc.) shorter inter-
vals between checks should be selected - please contact your ecom partner. All
ecom partners are listed under www.ecom.de.
ecom-DP
up to 0,5 % CH4
< 2 seconds
seeking out leakages!
Accurate concentration
approx. 180 sec.
- 5 to 40 °C
- 25 to 40 °C
20 to 80 % rF
155 x 35 x 22 mm
355 mm long
approx. 200 g