Power Wiring Examples

Refer to table on
Bonded Cabinet
Ground Bus *
CR1 *
24V AC/DC
or 120/240V AC
50/60 Hz
M1 *
Refer to Attention statement (Note 14).
Bonded Cabinet
Ground Bus *
324...528V AC rms
Three-phase Input
You must supply input power components. The three-phase line filter is wired
downstream of the circuit protection devices. Each drive module includes the
appropriate DC-bus link and connector set. The 24V supply can be jumpered
from drive-to-drive by using discrete wires or the shared-bus connection
system.
In this example, the inverter drives and optional capacitor modules are
downstream of a single DC-bus power supply.
Figure 126 - Kinetix 5700 Drives (single converter) Configuration
page 277
for note information.
Chassis
Customer Supplied
+24V DC
Power Supply *
Digital Input
(IOD) Connector
Grounding Screws/Jumpers
Note 12
EN+
EN–
START *
CR1 *
STOP *
CR1 *
Notes 10,15
Three-phase Input
Notes 1, 2
Circuit
M1
Protection*
Contactor*
Note 2
Note 10
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
2198-Pxxx
2198-Sxxx -ERSx or
Kinetix 5700
2198-Dxxx -ERSx
DC-bus Power Supply
Shunt Power
DC+
Cable Shield
(RC) Connector
SH
Internal Shunt
Note 11
DC Bus
DC+
DC+
(DC) Connectors
DC-
DC-
2198-TCON-24VDCIN36
24V Input Power
Wiring Connector
2
24V_COM
24V_COM
1
+24V
+24V
2198-xxxx-P-T
T-connectors and Bus Bars
1
Digital Input
IN1
2
Connections
COM
3
IN2
4
SHLD
Contactor Enable
CONT EN+
(CED) Connector
CONT EN–
Note 15
PE Ground
Note 9
(IPD) Connector
L3 L2 L1
2198-DBxx-F
Three-phase
AC Line Filter
Note 4
Interconnect Diagrams
Additional Inverters or
Capacitor Modules
Inverter
Note 7
Note 6
Clamp
4
U
3
Motor Power
V
2
(MP) Connector
W
1
2
MBRK -
Motor Brake
MBRK -
Motor Brake
(BC) Connector
1
MBRK +
Connections
MBRK +
Note 7
Control Power
(CP) Connectors
1
IN1
2
COM
3
IN2
Digital Input
4
Digital Input
(IOD) Connector
SHLD
Connections
5
COM
Note 7
6
IN3
7
COM
8
IN4
9
COM
10
SHLD
PE Ground
Note 9
* Indicates User Supplied Component
Appendix A
Three-phase
Motor Power
Connections
Notes 7,16