REPLACING THE CONDENSER FAN MOTOR

1. Remove the decorative grill
2. Disconnect the condenser fan motor lead from the cable or power PCB inside the electrical
box.
3. Remove the two screws (1) that mount the fan motor F0 (4) to the compressor base (2)
4. Take out the condenser fan motor and replace it. Make sure to refit the rubber washer (3) in
the original position and replace it if it shows signs of aging.

LEVELING THE DOOR / HINGE ADJUSTMENTS

1. With assistance, tilt the unit back and loosen the screws (1)
2. Adjust the glass door to make the door top is parallel with the cabinet top then tighten the
screws.
3.
Hinge adjustments are necessary when:
a. The door gasket is not sealed sufficiently along the hinge side of the door.
b. The door gasket is compressed more than 1/16" (1.5mm) on the hinge side (causing
a poor seal elsewhere around the top.)
c. The distance between the door and cabinet is greater at the top than at the bottom,
or vice versa.