Download Print this page
EdgeStar FP630 Service Manual
EdgeStar FP630 Service Manual

EdgeStar FP630 Service Manual

Portable freezer
Hide thumbs Also See for FP630:

Advertisement

Quick Links

Document Type: Service Manual
Version 1.1 10162017
SERVICE MANUAL
Portable Freezer
MODEL:
FP430, FP630, FP861
CAUTION: READ ALL SAFETY PRECAUTIONS IN THIS
MANUAL BEFORE SERVICING THE UNIT
EdgeStar, 8606 Wall St, Suite 1800, Austin, TX 78754
support.edgestarFRP ‡ VHUYLFH#HGJHVWDr.com ‡ HGJHVWDUFRP
*Warranty service should be performed by an authorized service representative only.

Advertisement

loading

Summary of Contents for EdgeStar FP630

  • Page 1 FP430, FP630, FP861 CAUTION: READ ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE SERVICING THE UNIT EdgeStar, 8606 Wall St, Suite 1800, Austin, TX 78754 support.edgestarFRP ‡ VHUYLFH#HGJHVWDr.com ‡ HGJHVWDUFRP *Warranty service should be performed by an authorized service representative only.
  • Page 2: Safety Precautions

    Always check line voltage and amperage. Always use exact replacement parts. Any attempt to repair a major appliance may result in personal injury and property damage. 1. Specifications Model FP430 FP630 FP861 Voltage / AC: 115V~60 Hz AC: 115V~60 Hz AC: 115V~60 Hz...
  • Page 3 2. Connection Note: Fuse is located within the DC plug connector. NOTE: Due to the difficulty in replacing a faulty temperature probe this unit comes pre-installed with two (2) probes. If a faulty temperature probe is suspected simply connect the unused probe in place of the faulty probe.
  • Page 4 4. Unit Not Cooling Troubleshooting Flow TROUBLESHOOTING TIPS AND NOTES: - Use of a multi-meter / voltage reader is recommended for proper diagnosis. Determining the point at which power is not properly passing into or through a component is the best method for determining component failure. If the unit does not appear to be receiving power: - Ensure that the power source is providing the proper voltage to the unit.
  • Page 5 5. Disassembly for Temperature controller 3.Remove screws(2) from the cabinet 4.Remove screws(2) from the box 5.Pull out the wire connector as the picture 6.Replace the new one...
  • Page 6 7. Cooling System Brief Description of System Flow Chart The refrigerant flows in the sequence: Compressor>Condenser>Filter>capillary Tube>Evaporator>compressor 1.Compressor 2.Control unit / Compressor Control Box 3.Power Supply 4.DC connector 5.AC connector 6.Condenser 7.Condenser fan...
  • Page 7 8. Power Supply and Compressor control 1.Remove screws(2) from the cabinet 2.Remove the grill 3.Remove screws(4) from the plate 4.Remove the power supply 5.Pull out the wire connector as the piceure...
  • Page 8 6.Remove the screw as the picture 7.Pull out it control...
  • Page 9 control...
  • Page 10: Revision Notes

    DATE REVISION NOTES: 10/07/17 Initial Document - V1.0 10/16/2017 Text and Title Edits - V1.1 EdgeStar, 8606 Wall St, Suite 1800, Austin, TX 78754 support.edgestarFRP ‡ VHUYLFH#HGJHVWDr.com ‡ HGJHVWDUFRP *Warranty service should be performed by an authorized service representative only.

This manual is also suitable for:

Fp430Fp861