Connecting I/O Terminal Block; Connecting Samples (Independent Operation Of Laser Marker) - Panasonic LP-400 Series External Control Manual

Laser marker
Hide thumbs Also See for LP-400 Series:
Table of Contents

Advertisement

2-3 Connecting I/O Terminal Block

2-3-1 Connecting samples (Independent operation of laser marker)

⿎ Connecting sample for NPN models
[LP-4xx(T)U / LP-4xx(T)U-A / LP-4xxS9(T)U / LP-4xxS9(T)U-A / LP-VxxU / LP-VxxU-A /
LP-W series]
• Connect A1 [+12V OUT] and A2 [IN COM.], B1 [0V OUT] and B2 [OUT COM.] as I/O power supply for marking.
• Connect B12 [EMER.+] and B11 [EMER.-] to release the emergency stop function. (Opening between B12 - B11 turns off
the laser pumping and marking is disabled.)
• Connect A12 [LASER STOP+] and A11 [LASER STOP-] to release the laser stop function. (Opening between A12 - A11
closes the internal shutter, and changes the status of the device into invalid for marking.)
• The following terminals are short-circuited by a short bar at factory shipment.
A1 [+12V OUT]
B1 [0V OUT]
B12 [EMER.+]
A12 [LASER STOP+]
Notice
• Short-circuiting IN COM. and OUT COM. in supplying power might cause the short out and also cause the trouble with
the laser marker.
• [IN COM.] and [OUT COM.] on the I/O terminal block are connected with [IN COM.] and [OUT COM.] on the I/O
connector respectively and internally. Therefore, inverting the power supply wiring for the I/O terminal block and the I/O
connector might cause a short circuit, resulting in the failure of the laser marker.
• Please make sure to check the power wiring before running the laser marker.
• When the laser marker is to be controlled by external power such as PLC, connect + side of the external power to A2 [IN
COM.] and - side to B2 [OUT COM.]. In this case, do not connect externally to A1 [+12V OUT] and B1 [0V OUT] of I/O
terminal block. (If a short bar is installed, remove it.) For details, refer to "2-3-2 Connecting sample with external devices"
(P.44).
Reference
• "Output simulation" and "I/O check monitor" can simulate ON/OFF state on each connector. Please use these functions
in checking the wiring. (Refer to the Operation/Maintenance Manual.)
42
A12 : LASER STOP +
A11 : LASER STOP -
B12 : EMER.+
B11 : EMER.-
A4 : TRIG.IN
A2 : IN COM.
A1 : +12V OUT
B2 : OUT COM.
B1 : 0V OUT
A2 [IN COM.]
B2 [OUT COM.]
B11 [EMER.-]
A11 [LASER STOP-]
ME-LP400V-EX-6
To manual door
To emergency stop switch
To sensor