2-2-2 Output rating and output circuit

The output rating and output circuit for the I/O terminal block and I/O connector are shown as follows:
⿎ Output rating
Item
Output form
Protection function for short-circuit
Max. output current
Max. applied voltage
Residual voltage
⿎ Output circuit
For NPN models
[LP-4xx(T)U / LP-4xx(T)U-A / LP-4xxS9(T)U /
LP-4xxS9(T)U-A / LP-VxxU / LP-VxxU-A / LP-W series]
⿎ Connecting image
For NPN models
[LP-4xx(T)U / LP-4xx(T)U-A / LP-4xxS9(T)U /
LP-4xxS9(T)U-A / LP-VxxU / LP-VxxU-A / LP-W series]
Each output
Output common
(OUT COM.)
I: I/O terminal block output: max. 50 mA, I/O connector output: max. 20 mA
Notice
• This product has NPN type and PNP type depending on the laser marker models. Make sure the model name and
connect correctly. (PNP type has "-C" in the end of the laser marker model name.)
• Do not short-circuit input common (IN COM.) and output common (OUT COM). It might cause the failure of the laser
marker.
Reference
• Respective outputs are photo-coupler outputs. The regulation for output ON is based on the ON status of photo-coupler.
• OUT COM. terminals on the I/O terminal block and on the I/O connector are the common terminals connected internally.
• Connect the power supply to IN COM. and OUT COM. by using either I/O terminal block or I/O connector.
Output on I/O terminal block
Photo-coupler (insulated output)
None
50mA
+30V DC
+2.0V DC or less
Output
Output common
(OUT COM.)
External power
+30V DC MAX
Load
ME-LP400V-EX-6
Output on I/O connector
20mA
For PNP models
[LP-4xx(T)U-C / LP-4xxS9(T)U-C / LP-VxxU-C]
For PNP models
[LP-4xx(T)U-C / LP-4xxS9(T)U-C / LP-VxxU-C]
Output common
(OUT COM.)
Each output
Output common
(OUT COM.)
Output
External power
+30V DC MAX
Load