Output
Rated Power
Surge Power ( Max. 1 Sec )
Surge Power ( Max. 3 Sec )
Maximum Output Power (1 Min)
Frequency
Protection
Output Overload & Short
Input Protection
Over Temperature
DC input Reverse Polarity
Environment
Working Temp.
Storage Temp.
Storage Temp. & Humidity
Control & Signal
Accessory (Optional)
LED Indicator
Dry Contact Terminal
Remote Control
Control & Signal
Dimension (WxHxD)
Packing
Cooling
Application
Output
AC Voltage
AC Regulation
Output Waveform
Input
DC Voltage
Voltage Range
No Load Current
Power Saving Mode
Protection
E ciency (Max.)
Input Under-Voltage Protection
Input Under-Voltage Recovery
Input Over-Voltage Protection
Input Over-Voltage Recovery
Safety & EMC
Safety Standards
EMC Standards
E-mark
*Warning:SP-2000/3000/4000 is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Quick Product Introduction
SP-700
SP-1000
700 VA
1000 VA
>1050VA ~ 1400VA
>1500VA ~ 2000VA
(151% ~ 200%)
(151% ~ 200%)
>810VA ~ 1050VA
>1150VA ~ 1500VA
(116% ~ 150%)
(116% ~ 150%)
>700VA ~ 810VA
>1000VA ~ 1150VA
(100% ~ 115%)
(100% ~ 115%)
50 / 60 Hz ± 0.5% (Dip Switch Selectable)
Shutdown output voltage, restart to recovery
Over / Under Voltage, Reverse Polarity (Internal Fuse)
o
o
Heat sink temperature over 80
C ± 5
C, shutdown output voltage, recover automatically after heat sink temperature goes down to 60
By Fuse
o
o
o
o
-20
C ~ 40
C, ( -40W/
C, 41~60
C )
o
o
-30
C ~ 70
C
10 ~ 95 % RH non-condensing
Remote Control:CR-8 / CR-16A; Transfer Switch:TR-40
Input voltage level, output load level and faulty status
By relay
6-port green terminal Terminal
200x83x330 mm /
200x83x372 mm /
7.87x3.27x12.99 inch
7.87x3.27x14.65 inch
2.6kg; 6pcs / 16.6kg /
3.26kg; 4pcs / 14kg /
3.59 CUFT
2.65 CUFT
Temperature & load controlled cooling fan
Home and o ce appliances, portable power equipment, vehicle, yacht and o -grid solar power
SP Series - 112
SP Series - 124
100 / 110 / 115 / 120 VAC (Dip Switch Selectable)
± 5%
Pure Sine Wave ( THD<5% @ Normal Load )
12VDC
24VDC
10.5~16.5VDC
21~33VDC
≦1.5A@12VDC
≦0.8A@24VDC
<0.1A@12VDC
<0.06A@24VDC
92%
93%
10.5 ± 0.3VDC
21 ± 0.5VDC
12.5 ± 0.3VDC
25 ± 0.5VDC
16.5 ± 0.3VDC
33 ± 0.5VDC
14.5 ± 0.3VDC
29 ± 0.5VDC
UL 458
(UL only for GFCI & Hard Wire)
FCC class B*
----
SP-1500
SP-2000
1500 VA
2000 VA
>2250VA ~ 3000VA
>3000VA ~ 4000VA
(151% ~ 200%)
(151% ~ 200%)
>1725VA ~ 2250VA
>2300VA ~ 3000VA
(116% ~ 150%)
(116% ~ 150%)
>1500VA ~ 1730VA
>2000VA ~ 2300VA
(100% ~ 115%)
(100% ~ 115%)
248x83x421 mm /
248x83x443 mm /
9.76x3.27x16.57 inch
9.76x3.27x17.44 inch
4.42kg; 4pcs / 22.68kg /
5.24kg; 4pcs / 21.96kg /
3.54 CUFT
3.58 CUFT
SP Series - 148
SP Series - 212
200 / 220 / 230 / 240 VAC (Dip Switch Selectable)
± 3%
Pure Sine Wave ( THD<3% @ Normal Load )
48VDC
12VDC
42~66VDC
10.5~16.5VDC
≦0.5A@48VDC
≦1.5A@12VDC
<0.05A@48VDC
<0.1A@12VDC
94%
94%
42 ± 1.0VDC
10.5 ± 0.3VDC
50 ± 1.0VDC
12.5 ± 0.3VDC
66 ± 1.0VDC
16.5 ± 0.3VDC
58 ± 1.0VDC
14.5 ± 0.3VDC
----
EN 60950-1
EN 55032 class B* ; EN 55024
EN 61000-3-2, -3-3 EN 61000-4-2, 3, 4, 5, 6, 8, 11
CISPR 25; ISO 7637-2
SP
Scan QR Code to view
the User Manual
SP-3000
SP-4000
3000 VA
4000 VA
>3450VA ~ 6000VA
>4600VA ~ 8000VA
(116% ~ 200%)
(116% ~ 200%)
>3000VA ~ 3450VA
>4000VA ~ 4600VA
(100% ~ 115%)
(100% ~ 115%)
o
o
C ± 5
C
255x158x442 mm /
255x158x462 mm /
10.04x6.22x17.40 inch
10.04x6.22x18.19 inch
8.2kg; 2pcs / 17.4kg /
10kg; 2pcs / 21kg /
3.05 CUFT
3.05 CUFT
SP Series - 224
SP Series - 248
24VDC
48VDC
21~33VDC
42~66VDC
≦0.8A@24VDC
≦0.5A@48VDC
<0.06A@24VDC
<0.05A@48VDC
94%
95%
21 ± 0.5VDC
42 ± 1.0VDC
25 ± 0.5VDC
50 ± 1.0VDC
33 ± 0.5VDC
66 ± 1.0VDC
29 ± 0.5VDC
58 ± 1.0VDC
2018.11_A0