Telecom / datacom pure sine wave inverter (30 pages)
Summary of Contents for Cotek SP-700-148
Page 1
User’s Manual SP Series SP-700/1000/1500/2000/3000/4000 [Page 3] PURE SINE WAVE INVERTER SP-700/1000/1500/2000/3000/4000 [Page 41] Signal de sortie sinusoï dal pur...
Page 3
3-2. DC Input Side (Rear Panel) Introduction 3-2-1. Remote Port (RJ-11) 3-2-2. Remote Control Green Terminal 3-2-3. General instruction before DC Input 3-2-4. Chassis Ground 3-3. Maintenance OPERATION 4-1. Connection the DC cable 4-2. Connecting the input power 4-3. Connecting the loads 4-4.
1. Safety Instructions 1-1. General Safety Precautions Warning! Before using the Inverter, read the safety instructions. Do not expose the inverter to rain, snow, spray or dust. To reduce the risk of fire hazard, do not cover or obstruct the ventilation openings and do not install the inverter in a zero-clearance compartment.
1-2. Other Safety Notes Upon receipt, examine the carton box for damage. If you have found any damage on the carton box please notify the company you purchased this unit from. Do not operate near water or in excessive humidity. ...
2. Functional Characteristics Introduction 2-1. System The unit is a highly reliable DC-AC inverter system, designed with advanced power electronic and microprocessor technology offering the following features: Pure sine wave output waveform O/P voltage 1xx : THD < 5 %, 2xx : THD <...
Page 14
interference in which case the user may be required to take adequate measures. Specification Model No. Electrical Item SP-2000-212 SP-2000-224 SP-2000-248 Voltage 12VDC 24VDC 48VDC Input Over-Voltage 16.5 ± 0.3VDC 33 ± 0.5VDC 66 ± 1.0VDC Protection Input Input Under-Voltage 10.5 ±...
interference in which case the user may be required to take adequate measures. 2-3-5. SP-3000 Specification Specification Model No. Electrical Item SP-3000-112 SP-3000-124 SP-3000-148 Voltage 12VDC 24VDC 48VDC Input Over-Voltage 16.5 ± 0.3VDC 33 ± 0.5VDC 66 ± 1.0VDC Protection Input Input Under-Voltage...
2-3-7. Voltage & temperature performance Figure 1. SP-700~2000 Figure 2. SP-700~2000 Output power vs. input voltage Output power vs. temperature Figure 3. SP-3000/4000 Figure 4. SP-3000/4000 Output power vs. input voltage Output power vs. temperature...
2-4. Mechanical Drawings Figure 5. SP series drawing (Top View) Figure 6. SP series drawing (AC output/Front View) Model A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Table 13. SP Series Dimension...
3. Installation and Maintenance 3-1. AC Output Side (Front Panel) Introduction Figure 7. SP-700/1000 AC output panel view Figure 8. SP-1500/2000 AC output panel view Figure 9. SP-3000/4000 AC output panel view Model SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Saving power adjustment Function switch Function LED TRC port (RJ-45)
3-1-1. Main Switch The 3-stage switch is for turning on, turning off and remote mode. 3-1-2. LED Indicator 3-1-2-1. Input voltage level: to display Input Voltages LED status DC 12V DC 24V DC 48V < 11.0V < 22.0V < 44.0V Orange 11.0 ~ 11.5V 22.0 ~ 23.0V...
LED status Status Recovery point Device startup — Orange process abnormal Under Temperature > 0℃ Orange Fast Protection Blink (Heat sink temp. under -20℃) Over Temperature < 60℃ Orange Slow Protection (heat sink temperature) Blink (Heat sink temp. over 80℃) Table 17.
3-1-3-3. Output Frequency Selection (S3) Frequency 50Hz 60Hz Table 20. Function Switch definition: Output Frequency selection 3-1-3-4. Power Saving Selection (S4) Saving function Power Saving OFF Power Saving ON Table 21. Function Switch definition: Power Saving selection 3-1-3-5. Power Saving Load Adjustment User can use variable resistor (VR) to set the input and wake up power saving threshold according to the load condition, and the setting range shows below:...
Pin Number Signal Description Bypass Transfer Relay Driver Signal Internal power for TR40 controller Internal power for TR40 controller The same polarity as the battery negative side Reserved Table 24. SP Series TRC Port : RJ-45. Figure 11. Wiring between SP series and TR-40 Note! The detail information please refer to TR-40 user manual 3-1-5.
Page 26
Socket Type Applicable Model SP-700/1000/1500/2000/3000- 212/224/248 SP-700/1000/1500/2000-112/124/148 SP-700/1000/1500/2000/3000- 212/224/248 SP-3000-112**/124**/148/212/224/248 SP-4000-124**/148/224/248 SP-700/1000/1500/2000/3000- 212/224/248 ** Neutral conductor (N) of the AC Ouput and Safety Ground (PE/GND) is connected Table 25. SP Series AC Socket vs. Model 3-1-5-2. SP-3000/4000 AC output interface Terminal Wire color Wire length / gauge...
3-2. DC Input Side (Rear Panel) Introduction Figure 12. SP-700/1000 Figure 13. SP-1500/2000 Figure 14. SP-3000/4000 Model SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Remote port (RJ-11) ① Remote control green terminal ② Chassis ground ③ DC input connector ④ Table 27. SP Series DC input side introduction...
3-2-1. Remote Port (RJ-11) The SP Series Inverter can be compatible with CR-8, and CR-16 remote control via RS-232 Communication. Before using the remote control, make sure the main switch on inverter must be at “ REMOTE” position. Pin Number Signal Description ①...
Caution! Please follow the following steps for the installation Before installing the inverter, make sure the main switch is at “OFF” position. Before using the remote function, make sure the main switch pressed toward “REMOTE” Use 20 ~ 24 #AWG wire to connect the remote control terminals Figure 16.
4. Operation 4-1. Connection the DC cable Connect DC input terminals to 12V / 24V /48V battery or other DC power source [ + ] is positive, [ - ] is negative. Reverse polarity connection can blow the internal fuse and may damage the inverter permanently. Figure 17.
Figure 18. Battery cabling 4-2. Connecting the input power Before making the DC input side connections , the main switch ④ must be at “OFF”. 4-3. Connecting the loads Calculate the total power consumption of the output load. Make sure that the total power consumption does not exceed the rated power.
5-2. RS-232 Port Operating The following steps show the connection among inverter and computer. Step 1 Connect the RS-232 port to the SP series unit on the front panel Step 2 Run the computer communication program Step 3 Set the transmission protocol Byte structure: START-BIP –...
Page 36
Function Command and description 0:No UTP Protection BIT9 1: UTP Protection 0:No OLPH Protection BIT10 1: OLPH Protection 0:No OLPL Protection BIT11 1: OLPL Protection Status definition refer to Table 36. Status definition Query the SP series DC input Format: VBAT? voltage of the battery Query the SP series output...
Page 37
SP-3000 ~ SP-4000 Status Definition Description Definition ID: ID Connection Error Sof Fail Protection Sof Fail: Soft Start Fail PLL: Phase lock loop Poff Protection Poff: Power off OOCP: Output Over Current Protection (Over Load > OOCP Protection 200%) OVP Protection OVP: Over Voltage Protection UVP Protection UVP: Under Voltage Protection...
COTEK local distributor. This warranty will be considered void if the unit has been misused, altered, or accidentally damaged. COTEK is not liable for anything that occurs as a result of the user’s fault.
Page 40
Table des matières CONSIGNES DE SÉ CURITÉ 1-1. Consignes d’ordre general 1-2. Précautions CARACTÉ RISTIQUES FONCTIONNELLES 2-1. Système 2-2. Schéma de principe 2-3. Caractéristique électriques 2-3-1. Modèles SP-700 2-3-2. Modèles SP-1000 2-3-3. Modèles SP-1500 2-3-4. Modèles SP-2000 2-3-5. SP-3000 Specification 2-3-6.
Page 41
3-2. Présentation du panneau arrière (cô té entrée CC) 3-2-1. Socle RJ-11 3-2-2. Bornier de la commande déportée (bornier vert) 3-2-3. Consignes générales – Entrée CC 3-2-4. Liaison à la masse 3-3. Entretien UTILISATION DE L’ONDULEUR 4-1. Bornes d’entrée courant continu 4-2.
1. Consignes de sécurité 1-1. Consignes d’ordre general Attention! Prendre le temps de lire les consignes de sécurité avant d’utiliser l’onduleur. Ne pas exposer l'onduleur à la pluie, à la neige, aux projections d'eau ou à la poussière. Pour réduire les risques électriques (incendie) ne pas couvrir ni obstruer les grilles de ventilation.
1-2. Précautions À réception, vérifier l’état de l’emballage. S’il est endommagé, en informer votre distributeur. Ne pas utiliser l’onduleur à proximité d’une source en eau ou dans un environnement excessivement humide. Bien serrer les branchements CC. La liaison à la masse doit être fiable et permanente. ...
2. Caractéristiques fonctionnelles 2-1. Système Le SP est un onduleur CC-CA de grande fiabilité, à base de composants électroniques et microprocesseurs dernière génération. Ils offrent les caractéristiques suivantes: Signal de sortie sinusoï dal pur 1xx:DHT < 5%, 2xx:DHT < 3% ...
2-3-7. Schémas de performances Sché ma 1 – SP-700~SP-2000 Sché ma 2 –SP-700~SP-2000 Puissance en sortie / Tension Puissance en sortie / d’alimentation Tempé rature Sché ma 3 – SP-3000~SP-4000 Sché ma 4 –SP-3000~SP-4000 Puissance en sortie / Tension Puissance en sortie / d’alimentation Tempé...
2-4. Dessins techniques Sché ma 5 – Onduleurs sé rie SP (vue de dessus) Sché ma 6 – Onduleurs sé rie SP (vue du panneau avant – sortie CA) Modèle A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) SP-700 SP-1000...
3-1-1. Interrupteur Il s’agit d’un interrupteur 3 positions (Marche / Arrêt / mode commande déportée). Repère sur les schémas. 3-1-2. Indicateur à LEDs 3-1-2-1. Tension d’alimentation LED tension 12V CC 24V CC 48V CC d’entrée Rouge < 11,0V < 22,0V <...
3-1-3. Introduction aux interrupteurs DIP Sché ma 10 – Interrupteurs DIP 3-1-3-1. Fonctions des interrupteurs DIP Interrupteur DIP Fonction Sélection de la tension de sortie Sélection de la tension de sortie Sélection de la fréquence Paramétrage du mode Standby (activé / désactivé) Tableau 18 –...
Page 62
3-1-3-3. Sélection de la fréquence (S3) Fréquence 50Hz 60Hz Tableau 20 – Sé lection de la fré quence 3-1-3-4. Paramétrage du mode Standby (S4) É tat Standby désactivé Standby activé Tableau 21 – Paramé trage du mode Standby 3-1-3-5. É talonnage du mode Standby L’utilisateur peut utiliser le potentiomètre pour définir les seuils mini et maxi du mode Standby en fonction de la demande, dans les limites indiquées ci-dessous.
3-1-5. Interfaces de sortie CA 3-1-5-1. Socles CA sur onduleurs SP Type de socle Disponible sur modèles SP-700/1000-112**/124**/148 USA(GFCI) NEMA 5-15R SP-1500/2000-112**/124**/148 USA(GFCI) NEMA 5-20R SP-700/1000/1500/2000/3000- 212/224/248 Australie / Europe Nlle-Zélande continentale SP-700/1000/1500/2000-112/124/148 SP-700/1000/1500/2000/3000- Universelle 212/224/248 SP-3000-112**/124**/148/212/224/248 SP-4000-124**/148/224/248 Bornier SP-700/1000/1500/2000/3000- 212/224/248 France **Le conducteur Neutre de la sortie CA et le conducteur de protection (PE/terre) sont...
3-1-5-3. Socle GFCI Modèles recommandés : Hubbel : type GF20 et GFRST20 – 125 V, 20 A Cooper : type VGF20 et SGF20 – 125 V, 20 A Leviton : type 7899-W et GFNT2 – 125 V, 20 A ...
Modèle SP-700 SP-1000 SP-1500 SP-2000 SP-3000 SP-4000 Socle (RJ11) ① Bornier commande déportée, vert ② Borne de liaison à la masse ③ Socle entrée CC ④ Tableau 27 – Pré sentation du panneau arriè re (cô té entré e CC) 3-2-1.
NB:défauts possibles : tension d’alimentation basse / haute, court-circuit (sortie CA), surcharge, température haute / basse. Attention:merci de respecter les instructions suivantes pour l’installation. S’assurer que l’interrupteur est en position « Arrêt » (OFF), avant d’installer l’onduleur. Avant d’utiliser la commande déportée, s’assurer que l’interrupteur est en position «...
4. Utilisation de l’onduleur 4-1. Bornes d’entrée courant continu Raccorder les bornes d’entrée courant continu à une batterie 12 V, 24 V ou 48 V ou à une source équivalente. [+] représente la borne positive, [-] la borne négative. Une inversion des pôles peut faire fondre le fusible interne et endommager irrémédiablement l’onduleur.
Sché ma 18 – Connexion batterie-onduleur 4-2. Connexions courant continu S’assurer que l’interrupteur sur l’onduleur est bien en position « Arrêt » (OFF) avant de raccorder l’entrée courant continu ④ 4-3. Connexions courant alternatif (consommateurs) Calculer la charge totale et s’assurer qu’elle ne dépasse pas la puissance nominale de l’onduleur.
5. Port de communication RS-232 5-1. Caractéristiques Le RS-232 est un port série permettant de contrôler l’onduleur via un ordinateur. Sché ma 19 – Câ ble RS-232 Onduleur SP Ordinateur Broche Description Broche Description Non utilisée Non utilisée Masse (GND) (réception données) (réception données) (transmission données)
Une fois la commande exécutée le système envoie une réponse de ce type : => CR LF: Commande exécutée avec succès ?> CR LF: Erreur, commande non acceptée Commande correcte mais erreur d’exécution ! > CR LF: (exemple : paramètres hors limites admissibles) 5-3-2.
Page 73
Fonction Commande et description ERR? (SP-3000~4000) Description 0: No ID Fail BIT0 1: ID Fail 0:No Sof Fail Protection BIT1 1:SofFail Protection 0:No PLL Fail BIT2 1:PLL Fail 0:No Poff Protection BIT3 1:Poff Protection 0:No Short Protection BIT4 1:Short Protection 0:No OOCP Protection BIT5 1: OOCP Protection...
Merci de contacter votre revendeur pour les interventions de maintenance ou les demandes en garantie. Cette garantie est considérée comme nulle en cas d’utilisation abusive, de modification ou de dommages par accident. COTEK ne saurait être tenu pour responsable d’aucun événement survenant suite à une faute de l’utilisateur.
Page 77
No.33, Sec. 2, Renhe Rd., Daxi Dist., Taoyuan City 33548, Taiwan Phone:+886-3-3891999 FAX:+886-3-3802333 http:// www.cotek.com.tw 2017.12._A2...