Programmable Function Settings - PowerTech PL300E User Manual

Sliding gate openers
Table of Contents

Advertisement

LED Display
"-L": The system learning is not done.
"OP": The system is in normal operation To
program, press SET button for 3 seconds,
when the LED display change from OP to 1,
press UP or DOWN to change function
settings (1 to P). Then press SET to enter the
sub function within each group, press UP or
Down to select sub functions and press SET
for confirmation.

3.4 Programmable Function Settings

LED Display
Definition
1
Options ofGate
Opening direction
2
Automatic Closing
There actions of the
photocells / safety edge /
3
loop detector when they
detecting obstacles
4
Motor Speed
(% full speed)
5
The deceleration setting
for gate moving
6
Deceleration Speed
(% full speed)
7
Over current setting
8
Programmable Functions
Function
1-1
Clockwise Opening
1-2
Counterclockwise Opening
2-0
No automatic closing
2-1
5 seconds
2-2
15 seconds
2-3
30 seconds
45 seconds
2-4
60 seconds
2-5
2-6
80 seconds
2-7
120 seconds
2-8
180 seconds
3-1
Please the function setting
3-2
after 8
3-3
4-1
50% Learning Speed
4-2
70% Learning Speed
4-3
85% Learning Speed
4-4
100% Learning Speed
5-1
75% of full distance
5-2
80%
5-3
85%
5-4
90%
95%
5-5
80%
6-1
60%
6-2
6-3
40%
6-4
25%
6-5
10%
7-1
2A
7-2
3A
7-3
4A
7-4
5A
7-5
6A
7-6
7A
INSTRUCTIONS PL300E/PL400E/PL500E/PL800E SLIDING GATE OPENER USER MANUAL
LED Display
"LE": Enter learning mode and then wait for
learning instructions.
"LP": The system learning is in progress.
The Auto-learning process of gate moving:
"Gate open to the end- stop close to the
end- stop."
"CL": Reset Factory Setting.
Value
1. The function can adjust the direction of gate opening.
2. The factory setting is "1-1".
1. This function can cause the gate toclose automatically
after the paused time.
2. The factory setting is "2-2": 15 Secs as the pause time.
1. Please do the function setting after H & J
2. The factory setting is "3-1".
1.The function can adjust the running speed of motor.
2.The factory setting is "4-4".
1. The factory setting is "5-1".
1. The factory setting is "6-4"
1. The function can adjust the running force of motor to
be compatible with the gate weight.
2. The factory setting is "7-5".
Programmable Functions
Description

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PL300E and is the answer not in the manual?

This manual is also suitable for:

Pl400ePl800ePl500e

Table of Contents

Save PDF