Troubleshooting
4. Troubleshooting
4.1
Error Codes and Description
System
Indoor
Unit
Outdoor
Unit
: Displayed only when system-down occurs.
70
Error
Codes
00
Normal
U0
Refrigerant shortage
Low-voltage detection or over-voltage detection
U2
Signal transmission error (between indoor unit and outdoor
U4
unit)
UA
Unspecified voltage (between indoor unit and outdoor unit)
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control/heating peak-cut control
Fan motor (DC motor) or related abnormality
A6
Indoor heat exchanger thermistor or related abnormality
C4
C7
Front panel open/close fault
C9
Room temperature thermistor or related abnormality
E1
Outdoor unit PCB abnormality
OL activation (compressor overload)
E5
Compressor lock
E6
E7
DC fan lock
E8
Input overcurrent detection
EA
Four way valve abnormality
Discharge pipe temperature control
F3
High pressure control in cooling
F6
F8
System shutdown due to compressor internal temperature
abnormality
H0
Compressor system sensor abnormality
H6
Position sensor abnormality
DC voltage/current sensor abnormality
H8
Outdoor temperature thermistor or related abnormality
H9
J3
Discharge pipe thermistor or related abnormality
J6
Outdoor heat exchanger thermistor or related abnormality
L3
Electrical box temperature rise
Radiation fin temperature rise
L4
Output overcurrent detection
L5
P4
Radiation fin thermistor or related abnormality
Description
SiUS041829E
Reference
Page
—
—
79
81
83
71
73
74
77
78
77
84
85
88
90
91
93
95
96
98
99
100
103
104
104
104
106
107
109
104
Part 6 Service Diagnosis