4. Field Settings

4.1

Temperature Display Switch

Procedure
 Press the upper side of Temp button and On button at the same time for 5 seconds to change
4.2

When 2 Units are Installed in 1 Room

Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding wireless
remote controller can be set for different address.
Both the indoor unit PCB and the wireless remote controller need alteration.
Indoor Unit PCB
1. Remove the front grille.
2. Remove the shield plate of the electrical box.
3. Cut the address setting jumper JA on the PCB.
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Part 7 Trial Operation and Field Settings
the unit of temperature display.
(R22009)
ADDRESS : JA
EXIST : 1
CUT : 2
JA
(Bottom of electrical box)
(R21128)

Field Settings

129