SiUS041829E
2.2
RX18RMVJU9
Main PCB
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
E1, E2
FU3
V3
V2
FU1
V1
Caution
Replace the PCB if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
Part 3 Printed Circuit Board Connector Wiring Diagram
S20
Connector for electronic expansion valve coil
S40
Connector for overload protector
S70
Connector for DC fan motor
S80
Connector for four way valve coil
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
HL1, HN1, S
Connector for terminal block
E1, E2
Terminal for ground
U, V, W
Connector for compressor
FU1, FU2
Fuse (3.15 A, 250 V)
FU3
Fuse (30 A, 250 V)
J6
Jumper for facility setting
Refer to page 131 for details.
LED A
LED for service monitor (green)
V1, V2, V3
Varistor
HL1, HN1, S
S80
S20
S40
S90
S70
Outdoor Unit
J6
LED A
U, V, W
FU2
2P443814-55
21