QUICK START GUIDE
Thermo Scientific Orion 7070iX
Total Residual Oxidant Analyzer
Figure 1 - Orion 7070iX TRO Analyzer
Unpacking the Orion 7070iX TRO Analyzer
Thermo Scientific
Orion
(TRO) Analyzer is assembled, tested and packaged with
great care.
1. Open the box and remove the accessories boxes from
the top, See "Figure 2 - Unpacking the 7070iX TRO
Analyzer".
CAUTION: The equipment exceeding 40 lbs.
should be lifted with the help of two persons
or follow any heavy lifting policies your
employer has put in place.
2. The shipping box contains the analyzer, LVD safety
manual, quick start guide and user manual usb drive.
3. Place the analyzer at a suitable location until installation
is completed.
Figure 2 - Unpacking the 7070iX TRO Analyzer
7070iX Total Residual Oxidant
Mounting the 7070iX TRO Analyzer
The Orion 7070iX TRO Analyzer should be installed in a
well ventilated location with ambient temperature between
5 °C and 45 °C (41 ° to 113 °F); and relative humidity must
not exceed 85% at 40 °C (104 °F). The area must be free
from dust, corrosive gases, vibration and shocks; sheltered
from direct sunlight, and shielded from dripping water.
1. Use four #10 screws or equivalent for proper support.
2. Refer to "Figure 3 - Dimension drawing of 7070iX
TRO Analyzer for mounting" for dimensions (in mm
and inches).
3. Make sure that the wall you choose can support the
weight of the instrument. (Approximately 20 kg or 44
lbs.)
4. Locate the instrument as close to the sampling point as
possible to ensure complete purging of the sample line
during each cycle.
5. Allow approximately 610 mm (24") of clearance on the
left side for door swing. Also, allow enough clearance on
the right side for wiring conduit.
6. Locate the Analyzer height such that the display is at
eye level for an operator, also allowing for appropriate
sample and drain connections.
7. Locate the dedicated external power switch or follow
local regulations for power supply.
Orion 7070iX TRO Analyzer

Advertisement

loading
Need help?

Need help?

Do you have a question about the Orion 7070iX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermo Scientific Orion 7070iX

  • Page 1 Total Residual Oxidant Analyzer Mounting the 7070iX TRO Analyzer The Orion 7070iX TRO Analyzer should be installed in a well ventilated location with ambient temperature between 5 °C and 45 °C (41 ° to 113 °F); and relative humidity must not exceed 85% at 40 °C (104 °F).
  • Page 2 ALLOW 24" (610 mm) CLEARANCE FOR DOOR SWING POWER SIGNAL 26.9" SAMPLE 27.9" (682 mm) IN 1/4" (707 mm) (6 mm) 12.4" 18.8" (315 mm) (476 mm) OVERFLOW DRAIN KEEP CLEAN SAMPLE RETURN DRAIN 1/8" (3 mm) 1/4" (6 mm) Figure 3 - Dimension drawing of 7070iX TRO Analyzer for mounting Plumbing the 7070iX TRO Analyzer The sample inlet is on the left of the analyzer.
  • Page 3 3. Put the reagent box on the the reagent holder with spigot facing upright. • The Orion 7070iX Total Residual Oxidant Analyzer ground connection can be made redundant through double 4. Push and turn the blue reagent adapter in clockwise grounding, either by doubling wires or using mounting direction onto reagent spigot.
  • Page 4: Instrument Operation Modes

    Instrument Operation Modes The setup menu allows you to run the Orion 7070iX Total Residual Oxidant Analyzer in different modes. There are 4 Instrument Operation Modes are available: • Continuous mode: The TRO Analyzer will run continuously and readings on the screen will be updated every 2 seconds.
  • Page 5 Orion 7070iX TRO Analyzer Focus on user benefits — we work closely with you to with experience that comes Global support - define your needs, and ensure you are using the analyzer in from supporting our customers for over a way that improves your bottom line. For more information,...