Gas conversion kits

Advertisement

Quick Links

All gas conversion must be done by a qualified service person in accordance with these instructions and in compliance with all codes and require-
ments. In Canada, gas conversion shall be carried out in accordance with the requirements of the Provincial Authorities having jurisdiction and in
accordance with the requirements of the CAN/CGA-B149.1 and .2 installation code.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause
property damage, injury, or death. For assistance or additional information, consult a qualified
FOR YOUR SAFETY
What to do if you smell gas:
• Do not try to light any appli-
ance.
• Do not touch any electrical
switch; do not use any phone
in your building.
• Immediately call your gas sup-
plier from a neighbor's phone.
Follow the gas supplier's
instructions.
• If you cannot reach your gas
supplier, call your fire depart-
ment.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other
appliance.
DANGER:
The conversion kit is to be
selected and installed by a qualified
service person in accordance with
these instructions and in compliance
with all codes and requirements of
authorities having jurisdiction. Failure
to follow instructions could result in
death, serious injury and/or property
damage. The qualified agency
performing this work assumes
responsibility for this conversion.
installer, service agency, or the gas supplier.
1. DANGER: Failure to comply will result in severe personal injury or death
and/or property damage.
2. WARNING: Failure to comply could result in severe personal injury or death
and/or property damage.
3. CAUTION: Failure to comply could result in minor personal injury and/or
property damage.
Application and Kit Selection
The gas conversion kits in these instructions are for Model FT and Model SFT
heaters equipped with a single-stage valve. See pages 6 and 7 for conversion kit
components.
Be sure that the kit selected applies to the model and size being converted.
DANGER: The gas burner in this gas-fired equipment is designed
and equipped to provide safe and economically controlled
complete combustion. However, if the installation does not permit
the burner to receive the proper supply of combustion air,
complete combustion may not occur. The result is incomplete
combustion which produces carbon monoxide, a poisonous gas
that can cause death.
Safe operation of indirect-fired gas burning equipment requires
a properly operating vent system which vents all flue products
to the outside atmosphere. FAILURE TO PROVIDE PROPER
VENTING WILL RESULT IN A HEALTH HAZARD WHICH
COULD CAUSE SERIOUS PERSONAL INJURY OR DEATH.
On separated combustion Model SFT heaters, install either the
horizontal or vertical combustion air/vent system illustrated in
the heater installation manual, using the concentric adapter
supplied. For installations of either Model FT or Model SFT,
always comply with the combustion air requirements in the
installation codes and instructions. Model FT units installed in
a confined space must be supplied with air for combustion as
required by Code and in the heater installation manual.
Combustion air at the burner should be regulated only by
manufacturer-provided equipment. NEVER RESTRICT OR
OTHERWISE ALTER THE SUPPLY OF COMBUSTION AIR
TO ANY HEATER. MAINTAIN THE VENT SYSTEM IN
PROPERLY OPERATING CONDITION.

Gas Conversion

INSTALLATION FORM RGM 432/433-GC (Version D.1)
Obsoletes Form RGM 432/433-GC (Version D)
APPLIES TO:
HAZARD INTENSITY LEVELS
Kits and
Instructions
Model FT and Model SFT
Mfg No. 148066, Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the FT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Reznor FT Series

  • Page 1: Gas Conversion

    Gas Conversion Kits and Instructions INSTALLATION FORM RGM 432/433-GC (Version D.1) Obsoletes Form RGM 432/433-GC (Version D) APPLIES TO: Model FT and Model SFT All gas conversion must be done by a qualified service person in accordance with these instructions and in compliance with all codes and require- ments.
  • Page 2: Gas Conversion Instructions

    Gas Conversion Instructions WARNING: Manufacturer of regulator spring kit Check kit contents for agreement with the parts list. A parts and gas valve must be the same. Spring kits of list for each kit is on pages 5-6. different manufacturers are not interchangeable, The kits listed in this manual are intended for use on units that and each spring kit must be used only in the valve will be operated at sea level.
  • Page 3 On the burner box end of the flexible hose, loosen the hose clamp. Slide the hose off the collar. Disconnect the silicone tubing from the static tap on the burner box cover. Remove the manifold seal plate and manifold cover plate. Remove the burner box cover. The manifold and burner rack assembly are visible.
  • Page 4 Gas Conversion Instructions (cont'd) MODELS FT 250 and FT 300 ONLY (does 5. Install or Remove Burner Air Restrictors - not apply to Model SFT) DANGER: Failure to install burner air restrictors according to directions could cause property damage, personal injury and/or death. 5A.
  • Page 5 6. Re-Assemble the Heater 7) If the gas valve has been adjusted for operation above 2000 ft, find the high altitude manifold pressure label in the kit. Using a Reverse the procedure in Step 4 to re-assemble the heater. Be cer- permanent marker, fill-in the pressure setting and adhere the tain that the manifold and burner rack are positioned properly.
  • Page 6 Conversion Kit Components - Natural to Propane All kits include the quantity of orifices required for the largest size of heater. Excess burner orifices or unused burner restrictors may not be returned for credit. Natural TO Propane Conversion Kit, P/N 179315 Natural TO Propane Conversion Kit, P/N 179327 Applies to Models FT 30, 45, 60, 75 and SFT 45, 60, 75 Applies to Models FT 250 and SFT 250...
  • Page 7 Conversion Kit Components - Propane to Natural All kits include the quantity of orifices required for the largest size of heater. Excess burner orifices may not be returned for credit. Propane TO Natural Conversion Kit, P/N 179316 Applies to Models FT 30, 45, 60, 75 and SFT 45, 60, 75 Components: Description 148059 Regulator Spring Conversion Kit, Robertshaw #A54301...
  • Page 8 REZNOR ©2014 Reznor LLC, All rights reserved. Printed in the U.S.A. MANUFACTURER OF GAS, OIL, ELECTRIC HEATING AND VENTILATING SYSTEMS 10/14 7M YL8588 Form 432/433-GC (Version D.1) Form 432/433-GC, Page 8...

This manual is also suitable for:

Ft 250Ft 300Sft seriesSft 250Sft 300Rgm 432-gc ... Show all