Vega EL 4 Operating Instructions Manual page 12

Conductive multiple rod electrode / conductive probe
Hide thumbs Also See for EL 4:
Table of Contents

Advertisement

5 Connecting to power supply
12
Fig. 5: Supplementary electronics for line break monitoring in conjunction with
VEGATOR 131, 132, 631, 632
1
Connection cable red - in conjunction with the VEGATOR 632 signal condi-
tioning instrument
Connection cable blue - in conjunction with the VEGATOR 131, 132, 631
signal conditionings instrument
Mounting - Supplementary electronics
To mount the supplementary electronics, proceed as follows:
1. Connect the eyelet according to the following illustration.
Make sure that the eyelets have no contact to other metal parts.
2. Open one of the other terminals and attach the additional elec-
tronics.
3. Tighten the terminal.
1
2
Fig. 6: Mounting of the additional electronics for line break monitoring
1
Connection to terminal 1 (ground rod = longest rod)
2
Connection to terminal 2 (max. rod = shortest rod)
3
Additional electronics for line break monitoring
If you are using a probe without additional electronics for line break
monitoring, a fault signal will be triggered.
1
3
Conductive probe EL 4 •