Installation & Maintenance Instructions
2-WAY DIRECT-ACTING SOLENOID VALVES
NORMALLY CLOSED OPERATION
LOW PRESSURE SERVICE
NOTICE:
See separate solenoid installation and
maintenance instructions for information on: Wiring,
Solenoid Temperature, Cause of Improper Operation, Coil
or Solenoid Replacement.
DESCRIPTION
Series 8030 valves are 2-way normally closed direct-acting
solenoid valves designed for low pressure service. Valves are
made of rugged forged brass or stainless steel. Series 8030
valves are provided with a general purpose solenoid
enclosure.
Series EF8030 and 8031 are the same as Series 8030 except
they
are
provided
explosionproof/
watertight solenoid enclosure.
OPERATION
Normally Closed:
Valve is closed when solenoid is
de-energized; open when energized.
NOTE:
No minimum operating pressure differential
required.
Manual Operator (optional feature)
Manual operator allows manual operation when desired or
during an electrical power outage. To engage manual
operator (open the valve). Turn manual operator stem
clockwise. Valve will now be in the same position as when
the solenoid is energized. To disengage manual operator,
turn stem counterclockwise.
CAUTION: Stem must be fully turned (rotated)
counterclockwise before operating valve electrically.
INSTALLATION
Check nameplate for correct catalog number, pressure,
voltage, frequency, and service. Never apply incompatible
fluids or exceed pressure rating of the valve. Installation and
valve maintenance to be performed by qualified personnel.
Future Service Considerations
Provision should be made for performing seat leakage,
external leakage, and operational tests on the valve with a
nonhazardous, noncombustible fluid after disassembly and
reassembly.
e
ASCO Valves
BRASS OR STAINLESS STEEL CONSTRUCTION
with
an explosionproof
MCMXCIX
All Rights Reserved.
3/8I OR 1/2I NPT
Temperature Limitations
For maximum valve ambient and fluid temperatures, refer
to chart below. Check catalog number prefix and watt rating
on nameplate.
Catalog
Watt
Number
Rating
Prefix
10.5 or
FT
15.4
None, DF,
10.1
SF, KF or
SC
10.1, 10.5
HT, KH,
or 15.4
ST or SU
or
None, KF,
SF or SC
16 1
16.1
HT, KH,
ST or SU
None or
11.2
HT
None, HT,
KF, KH,
11.6
SC, SF,
ST or SU
None or
16.8
HT
Positioning
Valve is designed to perform properly when mounted in any
position. However, for optimum life and performance, the
solenoid should be mounted vertical and upright to reduce
the possibility of foreign matter accumulating in the
solenoid base sub-assembly area.
Mounting
Refer to Figure 1 for mounting bracket (optional feature)
mounting dimensions.
.86
22
Figure 1. Mounting Bracket Dimensions.
Printed in U.S.A.
50-60 Hanover Road, Florham Park, New Jersey 07932
SERIES
8030
8031
Form No.V5304R3
Maximum
Coil
Ambient
Class
Temp.
122_F
F
(50_C)
125_F
F
(51.7_C)
140_F
H
(60_C)
125_F
F
(51.7_C)
140_F
H
(60_C)
77_F
F or H
(25_C)
F or H
104_F
(40_C)
77_F
F or H
(25_C)
.88
22
.58
.266 dia
15
.68
17
.125 R, 4 places
3.2
Page 1 of 3
www.ascovalve.com
Maximum
Fluid
Temp.
200_F
(93_C)
150_F
(65_C)
180_F
(82_C)
6.8

Advertisement

loading
Need help?

Need help?

Do you have a question about the 8030 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Asco 8030 Series

  • Page 1 .125 R, 4 places nonhazardous, noncombustible fluid after disassembly and reassembly. Figure 1. Mounting Bracket Dimensions. Page 1 of 3 Printed in U.S.A. MCMXCIX All Rights Reserved. ASCO Valves 50-60 Hanover Road, Florham Park, New Jersey 07932 www.ascovalve.com...
  • Page 2 Rebuild Kits. When Ordering Rebuild Kits for valve must be within range specified on nameplate. ASCO valves, order the Rebuild Kit number stamped on the S Excessive Leakage: Disassemble valve and clean all parts. valve nameplate. If the number of the kit is not visible, order...
  • Page 3 Indicates Parts Supplied In ASCO Rebuild Kits solenoid base sub-assembly core assembly with core spring stem pin body gasket valve body stem gasket stem partial view showing manaul operator 3/8 NPT Construction (optional feature) solenoid base sub-assembly core spring (wide end in core first,...

This manual is also suitable for:

8031 series