Monthly And Daily Loggers; Hour Counter - Kamstrup flowIQ 3100 Technical Description

Water meter
Hide thumbs Also See for flowIQ 3100:
Table of Contents

Advertisement

flowIQ® 3100

10.2 Monthly and daily loggers

The table below shows which registers are logged on the first day of the month, and which are logged
every day. The daily logger is an absolute log, i.e. current meter reading is logged every day.
Register type
Date (YY.MM.DD)
Volume V1
Operating hour
counter
Info
Vol Reverse
Date for max. flow
Max. flow V1
Date for min. flow V1
Min. flow V1
Min water temp.
Average water temp.
Max water temp.
Min. ambient temp.
Average ambient
temp.
Max ambient temp.
*)
Applies only for meter sizes 1.6, 2.5 and 4.0 m

10.3 Hour counter

Each info code, DRY, REVERSE, LEAK and BURST, has a corresponding hour counter. The hour counters are
incremented by one every hour, counted on the meter's clock, the corresponding info code is active.
Counting starts immediately the first time the info code is active within the hour in question. Even though
the info code occurs more than once within an hour, the counter is only incremented once. If the info code
remains active for several hours, the counter is incremented by one for each hour. The increment is
independent of how small a part of the hour the info code is active.
Please note: The info code DRY is set in two steps, the increment of the hour counter follows the second
step. See paragraph
The hour counters cannot be accessed directly but are represented in the info register in coarse resolution.
See paragraph
Info register
No hours are counted as long as the meter is in transport mode.
Ka st up A/S • Te h i al Des iptio • 5512-1242_D1_GB • 09.2016
Description
Logging time, year, month and day
Current meter reading (legal)
Accumulated number of operating hours
Info code
Volume during reverse flow
Date stamp of max. flow during period
Value for max. flow during period
Date stamp of of min. flow during period
Value of min. flow during period
The lowest measured water
*)
temperature during period
Volume weighted average water
*)
temperature during period
The highest measured water
*)
temperature during period
The lowest measured ambient/meter
temperature during period
Time weighted average ambient
temperature during period
The highest measured ambient
temperature during period
Info register
3
/h
TECHNICAL DESCRIPTION
Monthly logger
Daily logger
36 months
460 days
-
-
-
39