INFORMATION FOR MODELS G70C XXX
Pump Design ............................................Double Diaphragm
PRODUCT DATA
Wetted Parts
............................................................................
......Body and Check Valves ................................Polypropylene
........
......Diaphragm ....................................................Kalrez
Check Valve Seals..................................Viton
Ports ......................................................Air Inlet 1/4" (6.3 mm)
......Springs ..............................................................Hastelloy
Liquid Inlet 3/8" (9.5 mm) - 1/2" (12.7 mm) - 3/4" (19.1 mm)
Net Weight ....................................................1.2 lbs. (0.54kg)
Liquid Outlet 3/8" (9.5 mm) - 1/2" (12.7 mm) - 3/4" (19.1 mm)
DESCRIPTION
FLOJET Industrial G70C Pumps are designed for
general commercial and industrial applications. These
pumps are constructed from a selection of materials for
handling a broad range of chemicals
Allowed fluids for
Kalrez
®
parts
Lubricating Oils,
Hydraulic Oils,
Vegetable Oils,
Alcohols, Keytones,
Aromatic Hydrocarbons,
Aliphatic Hydrocarbons,
Diluted Acids, Alkalis,
Soaps with solvents,
Automotive brake fluid,
Acetones, Ethanol, inks.
MARKS AND GENERAL INFORMATION
In complicance with the 94/9/CEE standards, the pumps carry the
II 2G c IIB TX
following identification marks:
: safety symbol to Din 40012
II 2G: surface equipment for use in areas with the
presence of gases, vapors or mists in addition to
clouds of combustible dust in the air that occur
occasionally during normal operation (EN 1127-1
par. 6.3), both in external and internal areas
(ZONE 1).
c:
protection by constructional safety (EN 13463-5)
IIB:
Excluding the following products hydrogen,
acetylene, carbon disulphide.
TX:
Class of admitted temperatures. The processed
fluid temperature value must fall within such class
range and the user must comply with the
instructions contained in the manual and with
the current laws. Furthermore, the user must take
into account the ignition point of the gases, vapors
and mists in addition to clouds of combustible
powder in the air existing in the area of use.
®
®
6190
®
Extreme™
.
Not Allowed fluids for
Kalrez
®
parts
Halogenated Solvents
Note: Refer to page 4 for
General Safety Information.
Industrial Air Driven Pump
Liquid Temperature Range: ............40 - 120°F (4.4 - 48.9°C)
PERFORMANCE SPECIFICATIONS
Air ........................Inlet Pressure: ......20 - 100 PSI (1.4 - 6.9 Bar)
............................Inlet Temperature: ....40 - 130°F (4.4 - 54.4°C)
Environment Temperature: ..................40 - 130°F (4.4 - 54.4°C)
..............................Relative Humidity: ..................................0 - 1%
Priming ................Dry: ..............................................15 ft. (4.5 m)
Flow Rate ............................................Up to 5.0 GPM (18.9 LPM)
..............................Wet:................................................20 ft. (6.1m)
Noise Level ..........Max ..........................................................87dB
NOTE: Pump Operation must remain within tolerances specified above
®
®
Kalrez
and Viton
Extreme™ are trademarks or registered trademarks of DuPont Performance
Elastomers. DuPont is a registered trademark of DuPont and its affiliates.
®
Hastelloy
A registered trademark of Haynes International, Inc.
®
John Guest
A registered trademark of John Guest International, Limited
PERFORMANCE: KALREZ
¨
K a l r e z
D i a p h r a g m w i t h 1 / 2 Ó P o r t s
F l o w R a t e i n G P M ( 1 / m i n . )
Air In (PSI)
40
60
80
100
DIMENSIONAL DRAWING
Inches (millimeters)
3.21
(82)
2.20
(56)
4.52
(115)
0.71
0.92
Fluid In
(19)
(23)
1.84
(47)
G70C Series
.
®
WITH 1/2" PORTS
Air Flow Rate (SCFM)
1.0
1.3
1.7
2.2
4.58
(116)
5.81
(148)
Air Inlet
Fluid Out
0.25
(6.4
5.2
(134)
Air Exhaust
Muffler

Advertisement

loading

Summary of Contents for FLOJET G70C Series

  • Page 1 ® PERFORMANCE: KALREZ WITH 1/2” PORTS FLOJET Industrial G70C Pumps are designed for ¨ K a l r e z D i a p h r a g m w i t h 1 / 2 Ó P o r t s general commercial and industrial applications.
  • Page 2 MOUNTING source. Turn air off and disconnect air inlet line. (Standard The FLOJET G70C self-priming pump should be mounted in a brass air inlet ports have a check valve). dry and adequately ventilated area. This pump can be mounted several feet from the tank, above or below the fluid level. For DISASSEMBLY PROCEDURE recommended.
  • Page 3 MODEL G70C SERIES EXPLODED VIEW Part No. Description Part No. Description 20740122A Kit, Check Valve, Assy., Polypropylene 20758200A Kit Hardware - Includes ® ® Viton Extreme™, Hastelloy Screws #10 x 1.5” Hi Low ® 21000661A Kit, Diaphragm, Kalrez Retainer Clip Small 20751002A Kit, Shaft &...
  • Page 4 RETURN PROCEDURE To Reduce the risk of static sparking, ground the pump Prior to returning any product to FLOJET, call customer and all other equipment used or located in the pumping service for an authorization number. This number must be area.