Download Print this page

Fujitsu fi-7480 Service Manual page 9

Consumable replacement and cleaning instructions
Hide thumbs Also See for fi-7480:

Advertisement

fi-7480 / fi-7460
If you find the counts are close to or over 200,000 and cleaning doesn't
resolve a feeding issue it might be time to replace the consumables.
1. Checking and resetting the Sheet Counters After Consumable Replacement
a. Start up the Software Operation Panel (SOP)
b. From the listing on the left, Select "Device Setting"
c. Resetting the sheet counters
d. Click the "Clear(2) button for "Brake Roller" -> the counter is reset to "0"
e. Click the "Clear(3) button for "Pick Roller" -> the counter is reset to "0"
If the glass surface or the rollers are still dirty after they are wiped with a dry cloth, use a cloth moistened
with 90% or higher Isopropyl Alcohol. As the scanner continues to feed documents, paper dust will
accumulate inside the ADF and it may cause scanning errors. Cleaning should be performed
approximately every 5,000 sheers scanned.
The glass inside the ADF can be very hot when the scanner is being used. Before you start
cleaning the inside, make sure to turn off the power, unplug the power cable and wait at least 15
minutes for the inside of the ADF to cool down.
Note -
Do not use water or mild detergent to clean the ADF
When using Isopropyl Alcohol, use small quantities. Excessive amount of alcohol may take a
while to dry
Do not us alcohol on the plastic frame. It may deteriorate the frame