Cable (for example)
Fujikura
14.5-mm dia. 1,200 m (3937 ft) 100 m (328 ft)
Belden 9232
13.2 mm dia. 850 m (2789 ft)

Error messages

When an error is detected in the CCU or the camera, the
ALARM indicator turns on and an error message is displayed
on the CCU.
Error message
CCU: GEN LOCK NG
CCU: DPR NG
CCU: DM NG
CCU: SDP NG
CCU: PS FAN NG
CCU: PS CABLE SHORT
CCU: PS CABLE OPEN
CCU: PS RCP PWR
SUPPLY NG
CCU:RX WARNING

License Declarations

The CCU teleprompter video circuit uses MPEG-2 technology.
MPEG-2 Video Patent Portfolio License
ANY USE OF THIS PRODUCT OTHER THAN CONSUMER
PERSONAL USE IN ANY MANNER THAT COMPLIES WITH
THE MPEG-2 STANDARD FOR ENCODING VIDEO
INFORMATION FOR PACKAGED MEDIA IS EXPRESSLY
PROHIBITED WITHOUT A LICENSE UNDER APPLICABLE
PATENTS IN THE MPEG-2 PATENT PORTFOLIO, WHICH
LICENSE IS AVAILABLE FROM MPEG LA, L.L.C., 250
STEELE STREET, SUITE 300, DENVER, COLORADO
80206.
"PACKAGED MEDIA" means any storage media storing
MPEG-2 video information such as DVD movie which are sold/
distributed to general consumers. Disc replicators or sellers of
the PACKAGED MEDIA need to obtain licenses for their own
business from MPEG LA. Please contact MPEG LA for any
further information. MPEG LA. L.L.C., 250 STEELE STREET,
SUITE 300, DENVER, COLORADO 80206
http://www.mpegla.com
30
Appendix
Max. distance
Min. distance
75 m (246 ft)
Indication
External reference sync error
Front DPR board power supply, PLD
error
DM board power supply error
SDP board power supply error
Power supply block fan error
CAMERA connector optical fiber
cable or triax cable short circuit error
CAMERA connector optical fiber
cable or triax cable open circuit error
Remote control panel (connected to
REMOTE connector) power supply
error
Transmission error between camera
and CCU

Specifications

HSCU300RF/HSCU300R
General
Power supply
AC 100 to 240 V, 50/60 Hz
Current consumption
4.5 A (max)
5 °C to 40 °C (41 °F to 104 °F)
Operating
temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Storage temperature
Weight
Approx. 6.7 kg (14 lb 12 oz) (HSCU300RF),
Approx. 7.9 kg (17 lb 6.7 oz) (HSCU300R)
Input/output connectors
CAMERA
HSCU300RF
Optical fiber connector (1)
HSCU300R
Triax connector (1)
INTERCOM
XLR 5-pin (1)
INTERCOM/TALLY/
D-sub 25-pin, female (1)
PGM
• INCOM (PROD/ENG), 4W/RTS/CC,
0 dBu
• TALLY (R, G)
• PGM 2-system, –20 dBu/0 dBu/+4 dBu
REMOTE
8-pin multiconnector (1)
MIC/WF REMOTE/
D-sub 25-pin, female (1)
TRUNK
LAN
8-pin (1)
Input connectors
AC IN
(1), AC 100 to 240 V
SDI RETURN 1, 2
BNC type (2)
HD SDI: SMPTE 292M, 0.8 Vp-p, 75 Ω,
1.485/1.4835 Gbps bit rate
SD SDI: SMPTE 259M, 270 Mbps bit rate
BNC type (2), 1.0 Vp-p, 75 Ω
VBS RETURN 1, 2
REFERENCE IN/OUT BNC type (2), loop-through output
HD: SMPTE 274M, tri-level sync, 0.6 Vp-p,
75 Ω
SD: Black burst (NTSC: 0.286 Vp-p, 75 Ω/
PAL: 0.3 Vp-p, 75 Ω)
BNC type (2), VBS signal, 1.0 Vp-p, 75 Ω
PROMPTER 1, 2
2 systems