Error Messages

When trouble occurs with this unit, the following error
messages appear in the display window. The
displayed message will automatically disappear after a
few seconds. Pressing the CLEAR button also makes
the displayed message disappear.
Error messages Contents
Pac Err
Reception error on the S-BUS data link
Reset-P
The primary station has been reset.
Secret
A source set as secret is to be selected.
Com Err
Communication error of the S-BUS data
link
Protect
The destination is protected.
NotFound
The name cannot be found
Lvl Err
All levels are not controllable.
No Dest
The destination has not been set.
Not Avail
The source is out of the available souces. The source to be swithed is not found within the range of the
Remarks
If this occurs only once every several minutes, it is not a
problem. Power source noise or an S-BUS remote cable
longer than 500 m using BELDEN cable or equivalent may be
the cause. If the same errors still occurs on this unit when
used under conditions without the above causes, the trouble
may be in this unit.
This occurs when the primary station is turned on, or when
some trouble occurs in the S-BUS data link.
A source set as secret cannot be selected on a unit other than
the primary station.
This may occur when the communication period is too long.
The primary station may be turned off, or the remote cable may
be disconnected.
The protected destination cannot be switched. In the PRESET
display window, ID of the station which has set the protection
to the destination, is displayed.
The designated type name for type-number selection does not
exist in the table.
All levels are set not to be controlled.
The designated destination has not been set. Change the
selection or setting.
available sources. The source cannot be changed.