Chamberlain EL Series Programming Manual page 58

Telephone entry/access control system
Hide thumbs Also See for EL Series:
Table of Contents

Advertisement

Available languages

Available languages

Set Visitor Talk Time:
This feature sets the amount of time a visitor and resident may talk before the unit breaks communication. The
unit will beep 10 seconds prior to terminating a call. The resident may press "1" to reset the timer and extend
their talk time.
Factory Setting: 60 seconds
Press
Then
1
2
Enter Number of Seconds (15-250). Then (#)
Enable or Disable "Announce All Doors/Access Granted":
Announce access granted for all doors. If doors are in close aproximity know which door to gain access
through. Factory Setting: Disabled.
1
Press
Enable (1) or Disable (0). Then (#)
2
NOTE: Step 23, Enable or Disable "Access Granted" Beeps, controls announcement for door 1 ONLY.
Make sure Step 23 is enabled first, before enabling this step.
For EL2000SS ONLY:
Set Display Greeting:
Press
1
2
Enter Option:
0 - Alternate between Welcome and Instruction
Messages.
1 - Show welcome message ONLY.
2 - Show instruction message ONLY.
Return to Menu Programming:
Press
1
Press *** and the 6-Digit Password (2 short beeps will be heard)
If you make an error during an entry, press the asterisk key (*) to begin again.
5
Then
160
Then
25
Then
To enter programming mode from the unit
Exiting programming mode allows changes to take effect
EXAMPLE:
Sets the maximum time a visitor can talk
with a resident to "50" seconds.
* Use Versa XS 4.0 to modify any
Welcome or Instruction Messages.
57
26