4.1 - CLEANING
4.1.1 - Appliance and remote control cleaning
Use a dry cloth to clean the appliance and the remote control (fig. 44).
it is possible to use a cloth moistened with cold water to clean the appliance if it is very dirty.
Suck between the air inlet and outlet grilles (fig. 44).
Do not use a chemically treated or antistatic cloth to clean the appliance.
Do not use gasoline, solvent, polish or similar solvents.
These products could cause the breakage or deformation of the plastic surface.
4.1.2 - Cleaning the air filter
To ensure effective internal air filtration and satisfactory operation of your air
conditioner, the air filter has to be cleaned periodically.
The air filter is at the top of the unit.
Filter extraction:
a.
electrically disconnect the appliance.
b. Switch off the unit and wait for the closure of the suction flap.
c. Manually raise the air suction grille (3) (fig. 28).
d. Raise the front part of the filter (F) and slightly pull it towards yourself (fig. 39).
e. Extract the two additional filters (fig. 40) from the filter group (F):
(green purifying filter ref. F1 - black active carbons filter ref. F2).
f. Perfectly wash and dry all the filters.
Filter reassembly:
g. Insert the active carbons filter (black) (ref. F2) on the pins located on the front part of the filter (F) (fig.41).
h. Insert the purifying filter (green) (ref. f1) on the pins located on the front part of the filter (F) (fig. 41).
i.
Reassemble the filter (F) by inserting the rear edge inside the grille (fig. 42).
l.
Manually close the air suction grille (3) (fig. 43).
in order to remove the dirty filter signal, after connecting the air conditioner to the mains voltage, contem-
porary press, for at least 5 seconds, keys Stand-by and MODE located on the control panel (see figure B).
This way the dirty filter signal is removed and the related count is set to zero.
4.2 - MAINTENANCE
if you plan to idle the unit for a long time, perform the following:
a. Stop the air conditioner and disconnect the power supply.
b. remove the batteries from the remote control.
Do not perform them alone.
4.2.1 - Routine maintenance
the air conditioner that you have purchased has been designed to reduce routine maintenance operations
to a minimum.
these operations involve solely the cleaning operations outlined below:
• Cleaning or washing of the ambient air filter every 2 weeks or every time the relative red LED lights up
(this can be done by the user, see user manual).
• Cleaning of the condensing battery and cleaning of the condensate management system.