8
Error messages on the system
8.1
Phoenix / alpha Q system
The following error messages are displayed on operating units for welding machines of the Phoenix /
alpha Q series:
Error number
(display)
1
2
3
4
5
6
7
8
9
10
11
14
15
16
18
(1)
Error supported only if the system is equipped as such
099-000769-EW501
29.06.2015
Meaning
Mains overvoltage
Mains undervoltage
Inverter/inverter emergency stop circuit
(1)
temperature error
Low coolant level
Wire feed error
Shielding gas error
Secondary circuit overvoltage
Protective conductor error
(1)
System quick stop
Arc break error
Process ignition error
Wire feeder not detected
Wire feeder 2 not detected
Open circuit voltage reduction error
Speedometer error
Error messages on the system
Error can be reset
No, switch off machine
No, switch off machine
No, automatic reset
No, switch off machine
Yes
Yes
No, switch off machine
No, switch off machine
Yes
Yes
Yes
Yes
Yes
No, switch off machine
No, automatic reset
Phoenix / alpha Q system