CS-ME7CB1P
CS-ME10CB1P
CS-ME12CB1P
CS-ME14CB1P
CS-ME10CD3P
CS-ME14CD3P
Page
3
3
3
3
4
4
5
7
8
© 2003 Matsushita Electric Industrial Co., Ltd. All
rights
distribution is a violation of law.
ORDER NO. RAC0312001A8
Multi Air Conditioner
reserved.
Unauthorized
Page
8
10
11
12
13
14
14
15
copying
and

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic CS-ME7CB1P

  • Page 1: Table Of Contents

    ORDER NO. RAC0312001A8 Multi Air Conditioner CS-ME7CB1P CS-ME10CB1P CS-ME12CB1P CS-ME14CB1P CS-ME10CD3P CS-ME14CD3P Please file and use this manual together with the service manual for Model No. CS-ME7CKPG, CS- ME10CKPG, CS-ME12CKPG, CS-ME14CKPG, CS-ME18CKPG, CU-2E15CBPG, CU-2E18CBPG, CU- 3E23CBPG, CU-4E27CBPG, Order No. RAC0209005C2.
  • Page 2 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9 Operation Details (Functions & Protection) 12.1. Cassette Type (Indoor Unit: CS- 9.1. Simultaneous Operation Control ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P) 9.2. Airflow Direction Control (Cassette Type only) 12.2. Duct Type (Indoor Unit: CS-ME10CD3P/ME14CD3P) 9.3.
  • Page 3: Features

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 1 Features · Product − − − − A single OUTDOOR unit enables air conditioning of up to four separate rooms Remarks: 1. At least two indoor units must be connected.
  • Page 4: Functions

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 3 Functions 3.1. REMOTE CONTROL...
  • Page 5: Indoor Unit

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 3.2. INDOOR UNIT...
  • Page 6 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P...
  • Page 7: Product Specifications

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 4 Product Specifications Model CS-ME7CB1P CS-ME10CB1P CS-ME12CB1P CS-ME14CB1P CS-ME10CD3P CS-ME14CD3P Item Cassette Type Duct Type Power Source Outdoor power (single 230V 50Hz) Air Volume Cooling /min. Heating /min. 10.2...
  • Page 8: Dimensions

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 5 Dimensions 5.1. Cassette Type...
  • Page 9 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P...
  • Page 10: Grille

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 5.2. Grille...
  • Page 11: Duct Type

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 5.3. Duct Type...
  • Page 12: Refrigeration Cycle Diagram

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 6 Refrigeration Cycle Diagram...
  • Page 13: Block Diagram

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 7 Block Diagram CS-ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P/ME10CD3P/ME14CD3P...
  • Page 14: Wiring Diagram

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 8 Wiring Diagram 8.1. Cassette Type (CS-ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P)
  • Page 15: Duct Type (Cs-Me10Cd3P/Me14Cd3P)

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 8.2. Duct Type (CS-ME10CD3P/ME14CD3P)
  • Page 16: Operation Details (Functions & Protection)

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9 Operation Details (Functions & Protection) 9.1. Simultaneous Operation Control 1. Operation modes which can be selected using the remote control unit: Automatic, Cooling, Dry, Heating, Fan operation mode.
  • Page 17: Airflow Direction Control (Cassette Type Only)

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.2. Airflow Direction Control (Cassette Type only) The following shows how louver operation changes depending on the direction set with the AIR SWING button and other operating conditions. Cooling and Dry Heating ·...
  • Page 18: Indoor Fan Control

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.3. Indoor Fan Control · The following shows how fan speed changes depending on the setting made with the FAN SPEED button and other operating conditions. · Actual fan speed may differ from that you set with remote control.
  • Page 19 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P...
  • Page 20: Drain Pump Control

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.4. Drain Pump Control Basic operation · The drain pump starts 50 seconds after the indoor unit starts or the thermostat comes on (i.e., 10 seconds after the fan motor starts).
  • Page 21: Auto Restart Control

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.5. Auto Restart Control · if there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous operation mode and airflow direction. (Time Delay Safety Control is valid) 1.
  • Page 22: Other Indoor Unit Operation Functions

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.6. Other Indoor Unit Operation Functions 9.6.1. Auto button Proceed with operation when the air conditioner is stopped. (When the auto button is pressed during operation, the air conditioner is stopped.) 1.
  • Page 23 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P CHANGING THE REMOTE CONTROL TRANSMISSION CODE · When installing two air conditioners in one room, each air conditioner can be synchronized to the remote control. In order to operate separately, open the rear cover of one of the remote control and set to “B”.
  • Page 24 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.6.2. Drain Test (SW1) When installing the unit and you want the drain pump to operate independently, press the DRAIN TEST switch to operate it for about 5 minutes.
  • Page 25 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.6.4. Self Diagnosis display The diagnostic displays that appear when trouble has occurred can be checked using the remote control unit. When trouble occurs, operation is stopped automatically, and the timer lamp blinks. The diagnosis time has been reduced by warning the user by means of the blinking of the timer lamp.
  • Page 26 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 9.6.4.1. Error Cord Symbol Diagnosis Diagnosis method Indoor/Outdoor This trouble display appears when indoor/outdoor unit communication fails to be established after 30 or more abnormal seconds. communication <Diagnosis checkpoint>...
  • Page 27 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Symbol Diagnosis Diagnosis method Outdoor discharge Disconnected discharge sensor · When the condensation temperature is higher than the discharge temperature + (plus) 6 °C, a sensor pipe temp. sensor disconnection is detected, operation stops, and the trouble display appears (the timer lamp blinks).
  • Page 28 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Symbol Diagnosis Diagnosis method Indoor operating unit The restriction on the compressor frequency is started when the indoor unit heat exchanger temperature is freezing between 8 °C and 12 °C. Operation stops if a temperature below 0 °C continues for 6 minutes. Three minutes later, operation is started up at a temperature from 3 °C to 8 °C.
  • Page 29 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Symbol Diagnosis Diagnosis method IPM (Power transistor When this trouble is detected from the electrical parts radiation fin temperature sensor and OLP output during module) or operation, operation stops, and it is restarted 3 minutes later. If the trouble occurs on 4 occasions, operation compressor stops, and the trouble display appears.
  • Page 30: Installation Instructions

    10 Installation Instructions 10.1. Cassette Type Installation Instructions WARNING Required tools for Installation Works Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 1. Philips screw driver 7.
  • Page 31 Indoor Unit Accessory Parts Required Materials Other Items to be Prepared (Locally Purchased ) Accessory part Qty. Accessory part Qty. Accessory part Qty. Part name Part number Product name Remarks Piping insulation Battery Drain joint VP20 (outer diameter ø26) ; also sockets, elbows and other CZ-BT20P Decorative grille Rigid PVC pipe...
  • Page 32 Installation Dimensions Installing the Indoor Unit 1070 Grille • Select the unit position and airflow direction so that the Installation Dimensions (Unit: mm) Attach the nuts and washers to the cool and warm air spreads throughout the whole room. Connecting cable hanging bolts, then lift up and hook 770 Main unit •...
  • Page 33 Connecting the Indoor/Outdoor Connecting Cable • Remove the control box cover and insert the cable into the main unit • Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5 mm through the cable holder located on the side. flexible cord, type •...
  • Page 34 • When installing two air conditioners in one room, each air conditioner can be ENGLISH MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD. synchronized to the remote control. Web Site : http://www.panasonic.co.jp/global/ In order to operate separately, open the rear cover of one of the remote control and set F612424 to “B”.
  • Page 35: Duct Type

    10.2. Duct Type Installation Instructions WARNING Required tools for Installation Works Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire. 1. Philips screw driver 7. Reamer 14.
  • Page 36 Indoor Unit Accessory Parts Accessory part Qty. Accessory part Qty. Selecting the Installation Location Piping Drain hose insulation insulation Take into consideration the following contents when creating the blueprint. Receiver Band Remote control mounting location Indoor unit installation location The location should be strong enough to support the main unit Signals may not be transmitted and received correctly when without vibration.
  • Page 37 Installing the Indoor Unit (Installation embedded in the ceiling) • Always provide sufficient entry and exit space to allow installation work, inspection and unit Installing an Intake and Discharge Duct Type replacement. • Waterproof the rear surface of the ceiling below the unit in consideration of water droplets Allowable Duct bends forming and dropping.
  • Page 38 Securing the Hanging Bolts Reinforced concrete Wooden or other structure (Unit: mm) (Unit: mm) t =2 C channel Hanging Hanging fixture Insert hole-in Mounting the Receiver bolt M10 anchor, etc. Hanging bolt • Select a ceiling or wall position that does not block reception for the mounting location. Note that the receiver cord is 2.0 m.
  • Page 39 Connecting and Insulating Connecting the Indoor/Outdoor Connecting the Drain Piping the Refrigerant Piping Connecting Cable • Remove the control box cover and lead the connecting cable into the control box. • Align the center of the half-union and the connection pipe and •...
  • Page 40 Changing the remote control transmission code ENGLISH MATSUSHITA ELECTRIC INDUSTRIAL CO., LTD. • When installing two air conditioners in one room, each air conditioner can be Web Site : http://www.panasonic.co.jp/global/ F612425 synchronized to the remote control. PRINTED IN JAPAN In order to operate separately, open the rear cover of one of the remote control and set to “B”.
  • Page 41: Operating Instructions

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 11 Operating Instructions Contents SAFETY PRECAUTION BEFORE OPERATION Selection of easy operating modes (Automatic operation / Heating / Cooling / Dry / Air circulation operation) POINTS TO NOTE Names of parts and preparations...
  • Page 42 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Convenience Operation Convenience Operation Convenience Operation Convenience Operation After connecting the Continuously pressing the Automatic operation • power supply, press button, operation changes MODE Heating • Cooling • Dry •...
  • Page 43 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Names of Parts and Preparations Indoor unit Vertical air flow Horizontal air flow direction louvre Air outlet vent direction louvre Intake grille Air intake vent Indication panel Model number “POWER”...
  • Page 44 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Cassette Type When the intake grille is open To open Press in the 3 places shown. AUTO OPERATION BUTTON When not using the remote control. Push Push Push Continuously pressing the button for AUTO about 5 seconds, a “Beep”...
  • Page 45 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Names of Parts and Preparations Duct Type Indoor unit * Air intake vent * Air outlet vent Receiver unit * Not supplied by manufacturer. Receiver unit Remote control signal receiver...
  • Page 46 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Fan Speed / Air Swing Adjustment Changing the fan speed Press You may select from 5 stages of fan speed apart from the auto fan speed. Continuously pressing: The indication will change accordingly.
  • Page 47 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Fan Speed / Air Swing Adjustment Vertical air flow direction Setting automatic air flow directions HEATING During starting of operations and other circumstances when the air temperature is low, the air flow blows horizontally.
  • Page 48 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Care and maintenance Cassette Type Caution Ensure that the operation is stopped, Ensure that you are on firm footing power supply is off before you do the air before attempting to repair or service conditioner cleaning.
  • Page 49 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Care and maintenance Cassette Type Cleaning the intake grille (Must be removed from unit before washing) Center hinge Release lever Right hinge Left hinge Intake grille String (stops the grille from falling) Raise the intake grille (Keep hold of the intake grille when detaching it.)
  • Page 50 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Troubleshooting The following symptoms are not faults. Please continue to use it without fear. Is it faulty? No, it is okay Sound of flowing water: • Caused by the flow of refrigerant gas through the air conditioner system.
  • Page 51 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Helpful Information Helpful Information When the remote control is not available and the batteries are out. It is still possible for emergency operations. In this case, the unit will operate on the default temperature of 25°C.
  • Page 52 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Safety Precaution WARNING 1) This appliance must be earthed. 2) If the supply cord is damaged or needed to be replaced, it must be replaced by authorized service agent or a similarly qualified person in order to avoid a hazard.
  • Page 53: Disassembly Of Parts

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 12 Disassembly of Parts 12.1. Cassette Type (Indoor Unit: CS- ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P) 12.1.1. Detaching the fan motor and cross flow fan Open the air inlet section of the front grille.
  • Page 54 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P Detach the air guide and unscrew the screw on the heat exchanger. Detach the float switch and unscrew the 3 screws and disengage the 2 catches on the fan motor holder.
  • Page 55 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 12.1.3. Detaching the control board 1) Open the air inlet section of the front grille. 2) Unscrew the 4 screws on the front grille, then disengage the catches with a screwdriver and detach the front grille.
  • Page 56 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 12.1.4. Detaching the louver motor 3) Loosen the screw on the cover and detach the cover. 4) Unscrew the 2 screws on the control section cover and detach the connector for the louver motor.
  • Page 57: Duct Type (Indoor Unit: Cs-Me10Cd3P/Me14Cd3P)

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 12.2. Duct Type (Indoor Unit: CS-ME10CD3P/ME14CD3P) 12.2.1. Detaching the upper and inner casing 1) Unscrew the 4 screws on the upper and inner casing and detach them. 12.2.2. Detaching the control board 1) First detach the upper and inner casing (12.2.1.).
  • Page 58 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 12.2.3. Detaching the fan 1) First detach the upper and inner casing (12.2.1.). 2) Disengage the 4 catches (2 each on the left and right) on the air guide.
  • Page 59: Technical Data

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 13 Technical Data 13.1. OPERATION CHARACTERISTICS...
  • Page 60 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P...
  • Page 61 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P...
  • Page 62 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P...
  • Page 63: Electronic Circuit Diagram

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 14 Electronic Circuit Diagram 14.1. REMOTE CONTROL Remote Control Transmission Code Change Setting Remarks SEG10 SEG15 At product delivery COM0 SEG16 COM1 SEG17 COM2 SEG18 COM3 SEG19 SEG9 SEG20...
  • Page 64: Cassette Type

    14.2. Cassette Type ELECTRONIC CIRCUIT DIAGRAM CS-ME7CB1P,CS-ME10CB1P,CS-ME12CB1P,CS-ME14CB1P Microprocessor: A52D4956G123 VH5-3 ETXAC073X3B FUSE 3.15A S13050NA Pin No. Port No. Description CN-AC ERF7TJ100 10 A43BL18AG121 T001 G0B353D00002 B0EBNR000008 Buzzer Drive Thermal Fuse 100K 250VAC 0.01 Data Reception 1/4W 1000P ZNR1 250VAC (FC)
  • Page 65: Duct Type

    14.3. Duct Type ELECTRONIC CIRCUIT DIAGRAM CS-ME10CD3P,CS-ME14CD3P 250VAC 250VAC 4700P 2200P (ME) (ME) ELECTRONIC Microprocessor: A52D4956G123 VH7-4 ETXMJ251X1C 250VAC 250VAC 2200P 4700P CONTROLLER CN-AC J0JHC0000040 Pin No. Port No. Description (ME) (ME) T001 ERF10TK6R8 6.8 G0B273E00005 B0EBNR000008 FUSE D101 Buzzer Drive Thermal Fuse 250VAC SC201-4T...
  • Page 66: Exploded View & Replacement Parts List

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 15 Exploded View & Replacement Parts List 15.1. CS-ME7CB1P/ME10CB1P/ME12CB1P/ME14CB1P 15.1.1. Exploded View Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
  • Page 67 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 15.1.2. Replacement Parts List <Model: CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P> Ref. Part Name & Description Q´ty Part No. Remarks CS-ME7CB1P CS-ME10CB1P CS-ME12CB1P CS-ME14CB1P FLOAT SWITCH CWA12326 ← ← ← ←...
  • Page 68: Cs-Me10Cd3P/Me14Cd3P

    CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 15.2. CS-ME10CD3P/ME14CD3P 15.2.1. Exploded View Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
  • Page 69 CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P 15.2.2. Replacement Parts List <Model: CS-ME10CD3P / CS-ME14CD3P> Ref. No. Part Name & Description Q´ty Part No. Remarks CS-ME10CD3P CS-ME14CD3P FLOAT SWITCH CWA12161 ← ← ← ← l l l l...