Safety Precaution
1) This appliance must be earthed.
2) If the supply cord is damaged or needed to be replaced, it must be replaced by authorized
service agent or a similarly qualified person in order to avoid a hazard.
3) Remove power plug or disconnect from the main power supply before servicing this
appliance.
4) Do not repair by yourself.
In case of malfunction of this appliance, do not repair by yourself.
Contact to the sales dealer or service dealer for a repair.
5) Do not use in an explosive atmosphere.
Do not use this appliance in a potentially explosive atmosphere.
6) Turn off the power (Isolation from main power supply).
Pull off the power plug from the receptacle, or switch off the breaker, or switch off power
disconnecting mean to isolate the equipment from the main power supply in case of an
emergency.
* Airborne noise.
A-weighted sound pressure level of this appliance is less than 70dB (A) under the JIS
C 9612 test conditions.
Maximum cooling operation 1 m from the unit
Notes
• If the unit is not going to be used for an extended period of time, turn off the main Power
supply. If it is left at the ON position, approximately 14 W of electricity will be used even if
the indoor unit has been turned off with the remote control.
• If operation is stopped, then restart immediately, the unit will resume operation only after 3
minutes.
Use under the following conditions
DBT:Dry Bulb Temp
WBT:Wet Bulb Temp
Maximum Temperature
Minimum Temperature
WARNING
Cooling
Indoor
Outdoor
DBT WBT
DBT WBT
32
23
43
26
16
11
16
11
52
(Unit in °C)
Heating
Indoor
Outdoor
DBT WBT
DBT
WBT
30
24
18
2
-5
-6