Indoor Unit Accessory Parts
No.
Accessory part
Qty.
No.
Accessory part
Piping insulation
Battery
1
2
4
Band
Remote control holder
4
5
2
Remote control
Remote control holder
fixing screw
3
1
6
1
Selecting the Installation Location
Determine the location with the agreement of the customer.
Indoor unit
The location should be strong enough to support the main unit without vibration.
There should not be any heat or steam sources nearby.
Drainage should be easy. Avoid locating the drain port close to ditches
(domestic wastewater).
Avoid locations above entrances and exits.
Ensure the distances indicated by the
marks in the illustration.
Ensure sufficient space for installation and servicing.
The ceiling surface (lower surface) should be level.
Locate the indoor unit at least 1 m or more away from a TV, radio, wireless
equipment, antenna cables and fluorescent lights, and 2 m or more away
from a telephone.
Note that if the air conditioning unit is installed near an electronically lit
fluorescent light (inverter, rapid start type, etc.), it may not receive the
remote control signals.
To Drill a Hole in the Wall and
2
3
Selecting the Piping
Install a Sleeve of Piping
• Prepare the piping set shown in the table
1. Insert the piping sleeve to the hole.
below or equivalent products for the
2. Fix the bushing to the sleeve.
refrigerant piping.
3. Cut the sleeve until it extrudes
about 15 mm from the wall.
Liquid side
ø 6.35 (1/4") t 0.8
Gas side
ø 9.52 (3/8") t 0.8
When the wall is hollow,
please be sure to use the
* See the Outdoor Unit Installation
sleeve for tube ass'y to
Instructions.
prevent dangers caused by
mice biting the connecting
cable.
4. Finish by sealing the sleeve with
putty or caulking compound at the
final stage.
Required Materials
Qty.
No.
Accessory part
Qty.
Part name
Drain joint
Decorative grille
2
1
7
Pattern
1
8
1
Pattern fixing screw
9
2
4
Indoor Unit Installation Diagram
19 cm or
Indoor unit
Ceiling
more
30 cm or
20 cm
more
or more
Wall
Discharge vent
Intake
Indoor
Outdoor
Wall
15 mm
CAUTION
Approx.
5 - 7 mm
Sleeve for
tube ass'y
Bushing for
tube ass'y
ø70 through
Putty or caulking
hole
compound
Other Items to be Prepared (Locally Purchased )
Part number
Product name
VP20 (outer diameter ø26) ; also sockets, elbows and other
CZ-BT20P
Rigid PVC pipe
(white)
parts as necessary
Adhesive
PVC adhesive
For refrigerant piping insulation
(foamed polyethylene with a thickness of 8 mm or more)
Insulation
For drain piping insulation
(foamed polyethylene with a thickness of 10 mm or more)
4 × 1.5 mm
Indoor/outdoor
connecting cable
(See "Connecting the Indoor/Outdoor Connecting Cable".)
Hanging bolts (M10) (4) and nuts (12), Flat washers (8)
Hanging bolt related parts
Remote control mounting location
Signals may not be transmitted and received correctly when
the remote control is operated while in the holder. Take the
remote control in your hand to operate the unit.
Mount the holder in a location that is not subject to the
Decorative grille
effects of heat (direct sunlight and stoves, etc.).
Attaching the remote control holder to the wall
Remote control holder
fixing screws
6
30 cm or
Remote control
more
holder
5
Remarks
2
flexible cord, type designation 245 IEC 57 (H05RN-F)
Remote
control 3

Hide quick links: