Panasonic CS-ME7CB1P Service Manual page 36

Multi air conditioner
Table of Contents

Advertisement

Indoor Unit Accessory Parts
No.
Accessory part
Qty.
No.
Accessory part
Piping
Drain hose insulation
1
insulation
1
7
Receiver
Band
2
2
8
Receiver cover
Remote control
9
1
3
Receiver mount
Battery
10
4
2
Clamp
Remote control holder
5
1
11
Remote control holder
Clamp mounting screw
fixing screw
6
2
12
Required Materials
• Read the catalog and other technical materials and prepare the required materials.
Other Items to be Prepared (Locally Purchased)
Product name
Remarks
VP20 (outer diameter ø26); also sockets,
Rigid PVC pipe
elbows and other parts as necessary
PVC adhesive
Adhesive
For refrigerant piping insulation (foamed
polyethylene with a thickness of 8 mm or more)
Insulation
For drain piping insulation (foamed polyethylene
with a thickness of 10 mm or more)
4 × 1.5 mm
2
flexible cord, type designation
Indoor/outdoor connecting cable
245 IEC 57 (H05RN-F)
Hanging bolts (M10) (4) and nuts (12), Flat
Hanging bolt related parts
washers (8) (when hanging the indoor unit)
Qty.
1
Selecting the Installation Location
1
Take into consideration the following contents when creating the blueprint.
Indoor unit installation location
1
The location should be strong enough to support the main unit
without vibration.
There should not be any heat or steam sources nearby.
1
Drainage should be easy. Avoid locating the drain port close to
ditches (domestic wastewater).
Avoid locations above entrances and exits.
Do not block the intake and discharge.
1
Select the location so that the cool and warm air spreads
throughout the entire room.
Locate the indoor unit at least 1 m or more away from a TV, radio,
wireless equipment, antenna cables and fluorescent lights, and 2
2
m or more away from a telephone.
Note that if the air conditioning unit is installed near an
2
electronically lit fluorescent light (inverter, rapid start type, etc.),
it may not receive the remote control signals.
2
Selecting the Piping
• Prepare the piping set shown in the table
below or equivalent products for the
refrigerant piping.
Liquid side
ø 6.35 (1/4") t 0.8
Gas side
ø 9.52 (3/8") t 0.8
* See the Outdoor Unit Installation
Instructions.
Remote control mounting location
Signals may not be transmitted and received correctly when
the remote control is operated while in the holder. Take the
remote control in your hand to operate the unit.
Mount the holder in a location that is not subject to the
effects of heat (direct sunlight and stoves, etc.).
Attaching the remote control holder to the wall
Remote control holder
fixing screws
6
Remote control
holder
5
To Drill a Hole in the Wall and
3
Install a Sleeve of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
Indoor
Wall
3. Cut the sleeve until it extrudes
about 15 mm from the wall.
CAUTION
When the wall is hollow,
Sleeve for
please be sure to use the
tube ass'y
sleeve for tube ass'y to
prevent dangers caused by
mice biting the connecting
cable.
ø70 through
4. Finish by sealing the sleeve with
hole
putty or caulking compound at the
final stage.
Remote
control 3
Outdoor
15 mm
Approx.
5 - 7 mm
Bushing for
tube ass'y
Putty or caulking
compound