9.6.

Other Indoor Unit Operation Functions

9.6.1.
Auto button
Proceed with operation when the air conditioner is stopped.
(When the auto button is pressed during operation, the air conditioner is stopped.)
1. Emergency operation
Press the auto button and release it within 5 seconds to perform emergency operation.
Under normal condition (failure is not occurred) automatic operation is performed. In the event of a failure that still enables
operation to be performed, emergency operation is performed.
2. Forced cooling operation
Press the auto button about 5-8 seconds (1 beep sound) to perform the forced cooling operation.
The air conditioner does not operate for 2 minutes if the room temperature is low (intake temperature below 16 °C) so
just wait. The forced operation is performed after the 2 minutes have elapsed.
3. Forced heating operation
Press the auto button about 8-11 seconds (2 beeps sound) to perform the forced heating operation.
4. Setting modes (Remote control transmission code, current switching mode)
The remote control transmission code selection mode is established by pressing the AUTO button about 11-16 seconds (3
beeps sound).