Download Print this page
Emerson Sola HD GLQ250 Series Installation & Operating Instructions

Emerson Sola HD GLQ250 Series Installation & Operating Instructions

Advertisement

Quick Links

GLQ252-C, GLQ253-C Installation & Operating Instructions
To comply with the published safety standards, the following must be observed when using this
power supply:
1. Maximum ambient temperature for the power supply must not exceed 50°C.
2. When installing the power supply in the end-use equipment, special attention is required
to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1,
IEC60950-1, and CSA22.2 No. 60950-1-03; including the requirements for creepage
distances, clearances, and distance through insulation between primary wiring and earth or
secondary (SELV) wiring.
3. The power supply's rated input voltage is automatically selected. Please refer to the specifi-
cation sheet for the input voltage range.
4. The maximum output power of the supply must not exceed the rating indicated in the specifi-
cation sheet.
5. The earth ground wire must be connected only to the point marked with the earth ground
symbol (on the unit).
6. The disconnection from the line must be in the end system.
7. Hazardous voltages exist in the primary circuits. Disconnect the power supply before
servicing.
8. The unit must be protected by a fuse in the end system. Components, such as capacitors, may
be positioned in front of the internal fuse.
9. When operating with a dc input voltage range, the dc source must be rectified from a mains
supply not exceeding 250 V ac. The unit input must also be protected by a dc rated fuse in
the end-use installation system.
10. The internal fuse should only be replaced with a F6.3AH, 250 V ac, type 21606.3 manufac-
tured by Littelfuse, type 50CF063H manufactured by Triad, or type S501 manufactured by
Cooper.
11. This equipment is considered Class I according to protection against electric shock.
12. This power supply is
marked following the provisions of the Low Voltage Directive,
2006/95/EC.
13. For technical assistance, contact SolaHD Technical Support at (800) 377- 4384 or send an
e-mail to tech@solahd.com. Please visit our Web site at www.solahd.com for additional
product information and specification sheets.
Output Ratings
Model
Output Voltage (V)
+5
+12
GLQ252-C
-12
+5 to +25
+5
+15
GLQ253-C
-15
+5 to +25
Visit our Web site at www.solahd.com or contact Technical Support at (800) 377- 4384 with any questions
30 CFM Forced Air Cooling
(unit not convection rated)
Max. Output Current (A) Max. Output Power (W)
35.0
10.0
6.0
6.0
250 with cover
35.0
10.0
6.0
6.0
Mechanical Outline
R10
R9
R13
R26
L
R32
N
N
L
3
2
SK1
1
Connector PIN Designation
Input Connector
PIN
1
SK1
2
3
Output Connector
PIN
A
Bus Bar
B
1
2, 3
4
SK2
5
6
1
2
3
4
SK3
5
6
7
8
1
SK4
2
1
SK5
2
1
SK7
2
A
C36
C35
L16
A
Bus Bar
L6
L4
B
B
6
C37
C38
R76
B
5
4th O/P Adj.
4
3
O/P Adj.
L11
2
B
C42
1
SK4
1
1
SK7
B
2
1
2
SK3
L10
SK5
L14
A
B
8
GLQ252-C
GLQ253-C
Neutral
Line
Earth GND
GLQ252-C
GLQ253-C
+5 V
Common
+12 V
+15 V
Common
-12 V
-15 V
Return (float)
+5 V to +25 V adj. (float)
+Sense
-Sense
Inhibit (normally open)
Inhibit (normally closed)
Common
Active current share
P OK
Dc OK
Fan (+)
Fan (-)
+5 V (aux)
Common
Fan (+)
Fan (-)
P/N: A272-194 Rev 0 6/4/09 Ref: 03361002202
SK2

Advertisement

loading

Summary of Contents for Emerson Sola HD GLQ250 Series

  • Page 1 GLQ252-C, GLQ253-C Installation & Operating Instructions Mechanical Outline To comply with the published safety standards, the following must be observed when using this power supply: 1. Maximum ambient temperature for the power supply must not exceed 50°C. 2. When installing the power supply in the end-use equipment, special attention is required to ensure safety compliance with the following safety standards: UL60950-1, EN60950-1, Bus Bar IEC60950-1, and CSA22.2 No.
  • Page 2 GLQ252-C, GLQ253-C Installation & Operating Instructions Mechanical Dimensions Typical Ventilation Setup 2.01 9.00 [228.6] .59 [15.0] 1.87 [51.0] 2.50 [63.5] [47.5] max. max. with BASEPLATE cover (0.039 in/1mm THK. SHEET ALUMINIUM) 1.18 [30.0] 8.52 [216.4] [6.1] Side View POWER SUPPLY 10.00 [254.0] 5.00 [127.0] UNIT...
  • Page 3: Electrical Specifications

    GLQ250 Series Specifications Electrical Specifications Input Input ra nge 85-264 Vac; 120-300 Vdc Frequency 47-440 Hz 20 A max, cold start @ 25°C Inrush current Efficiency 75% typical at full load FCC Class B conducted and radiated; CISPR 22 Class B conducted and radiated; EMI filter EN55022 Class B conducted and radiated;...

This manual is also suitable for:

Sola hd glq252-cSola hd glq253-c