Specifications

Control Console
Enclosure:
Control:
Interface:
Operation:
Relay Output: 3 Outputs (All Clear, Warning and Alarm. 1 amp, 24Vdc or 120Vac)
Weight:
Colour:
Power Supply:
Wireless Frequency:
Sensor Assembly
Construction:
Lightning Discharge
Detection Range:
Electric Field
Measurement:
Relay Output:
Wireless Frequency:
Colour:
Weight:
Power Supply:
Siren:
Solar Panel
Voltage:
Power:
Size:
Weight:
Type:
Die-cast, 170mm (L) x 120mm (W) x 50mm (H)
Micro Processor
Webpage (default address 192.168.1.90)
Console receives Electrostatic Field measurements and event
notification from sensors in the field and displays received
information on an easy to read webpage. Allows users to
download and save a log of events that have occurred. Allows
users to change a range of settings.
840g
Grey
6V plug pack (110V-240V)
2.4GHz
Stainless Steel
Far Strikes, Approx 10-25km
Near Strikes, < Approx 10km
Negligible, Approx ±0-3kV/m
Low E-Field, Approx ±3-7kV/m
High E-Field, Approx ±7-10kV/m
3 Outputs (All Clear, Warning and Alarm. 1 amp, 24Vdc or 120Vac)
2.4GHz
Stainless Steel
8kg
Package A 110V-240V, UPS 3 hours uptime.
Package B 12Vdc Solar Panel and storage battery
10W, 8 ohm approximately 117dbm.
12V
20W
639 x 294 x 23mm
2.4kg
Monocrystalline

Advertisement