Settings:
System Status
This page is similar to the main page but has the addition of a Status Table.
The Status Table lists all the LWS Entities that are currently connected or have been connected to
the radio network. An entity can be either the Console or the Sensor or one of the range extenders (if
used). Each entity gives its Name , Voltage, Signal Strength and it's communications status.
Sometimes some of the readings will be Red or Orange in colour, if these colours persist it indicates a
possible problem. If a voltage or signal strength reading goes red occasionally but comes back green
it is not a problem, just a missed packet. At startup the readings will all be Red for the first couple of
minutes. Don't worry about this.
Generally the voltage should be above 11.3 volts, except for the console, which should be 6 volts.
Generally the signal strengths should be between -35.db and - 85.db. The closer the signal strength is
to zero the stronger it is.