11 Technical specifications

Power supply
Absorbed power
Operating range
Precision
Resolution
Storage conditions
Operating conditions
External fuse (obligatory)
Mounting
Case
Index of protection
Connections
Classification
for
protection
electrical shocks
Number of cycles of automatic operations
(i.e.: relays)
Obsolescence (working hours)
Type of action of micro switches
PTI insulation material
Time during which insulation components
undergo electrical stress
Ambient pollution
Resistance to heat and fire
Immunity against over voltage
Class and structure of the Software
Analogue inputs
Digital inputs
Analogue output
Digital output
Aux. Power supply output (for probes)
Serial line (optional)
Display
Indications
FCM electronic regulator - Preliminary version
24 Vac/dc, -20%, +10%, 50/60Hz. In case of alternating current, use a 10V transformer at
least
3 VA
temperature
pressure
humidity
FCM00NTC00
FCM000*000
FCM00NTC00
FCM000*000
÷
-10T70 (-10
70°C, 14÷158°F), below 90% rH non condensing
÷
0T50 (0
50°C, 32÷122°F), below 90% rH non condensing
315 mA T
DIN rail
Plastic: dimensions72x88x64 mm
IP20 (IP40 with panel mounting)
Screw terminals for wires with max. 1.5 mm²/min. 0.5 mm² cross-section
against
Class II
Low tension components have reinforced insulation if compared to very low tension ones. There is
supplementary insulation between very low tension components and the front panel. The very low
tension components (probe inputs, digital inputs, serial connection and power supply) do not have
any insulation.
100,000
60,000 hours
Type 1C complying with ECC EN 60730-1 standards
250V
Long
Normal
Category D (self-extinguishing complying with UL94-V0)
Category II
Class A
FCM00NTC00
FCM0001000
FCM0002000
2 voltage free, programmable by the user:
max. voltage with open contact 5Vdc
max. current with closed contact 5mA
max. resistance 50
÷
1 at 0
10 V; I max =5 mA, min. load 2 k
1 SPDT relay-programmable by the user: I max =8 A res.(2A), Vac max =250 V
12 Vdc, +10%, I max =50 mA total
2-lead RS-485
3 digits, 7-segment LED indicators
LED for active analogue output and special function
÷
÷
-40T100 (-40
100°C; -40
÷
0.0
100 bar
÷
0,0
100% rH
÷
1°C within the range -10
100°C, 14÷212°F
÷
2°C within the range -40
-10°C, -40÷14°F
1% of full scale
0.1°C(°F) within the range -9.9
max 0.1% of full scale; min 0,1 within the range -9.9/ 99.9; 1
otherwise
2 for probes NTC CAREL 10 k
(response time depends on the type of component)
÷
2 0
10 V inputs (min. response time 100 ms)
÷
÷
2 0
20 mA or 4
20 mA inputs (min. response time 100 ms)
; precision 1% of full scale
32
212°F)
÷
99, 9°C(°F); 1°C(°F) otherwise
at 25°C
Cod. +302235300 - Rel. 2.0 del 30/11/98