Repair
8. Probe inside the pot from the outlet until the debris
is found.
9. Remove debris, inspect the gasket and replace if
damaged. Reinstall the outlet manifold and torque
the clamp to 15 ft-lb (19.5 N•m).
NOTE: When debris is cleared, media should freely
flow from the pot outlet. The pot will need to be com-
pletely flushed before the outlet manifold can be
reinstalled. All disposals must comply with national,
state and local regulations.
10. Connect the abrasive hose at the cam-lock connec-
tions.
11. Inspect the post funnel assembly gaskets and
replace if necessary. Reinstall the pot funnel
assembly and torque to 70 +/- 5 ft-lb (95 +/- 7 N•m).