Assignment And Connection Of The Vld / Vhd Terminal Block - Procon V3D Series Instruction Manual

Frequency converters
Hide thumbs Also See for V3D Series:
Table of Contents

Advertisement

H - I - J
 ASSIGNMENT AND CONNECTION OF THE VLD / VHD TERMINAL BLOCK
M
~
U
V
MOTOR
SA
1
2
3
4
2-10K
0÷10V
(0)4÷ 0
2 mA
Three-colour LED (green: On, yellow: Operate, red: Error)
SA1 +10V potentiometer driving output (max. 6 mA) (+15 V, +5 V option)
SA2 Analogue input 1 (+):
SA3 Analogue input 1 (–):
SA4 Analogue input 2 (+):
SA5 Analogue input 2 (–):
SA6 GND/A (reference point of the analogue inputs and outputs)
SA7 Analogue 1 output: 0÷10V, (0)4÷20mA, (or Analogue input 3: 0÷10 V option)
SA8 Analogue 2 output: 0÷10V, (0)4÷20mA, (or Analogue input 4: 0÷10 V option)
SD1 Digital input 1 * (factory setting: start switch)
SD2 Digital input 2 * (factory setting: reversing switch)
SD3 Digital input 3 * (factory setting: jogging switch)
SD4 Digital input 4 * (factory setting: error acknowledgement)
SD5 Digital input 5 * (factory setting: external error), (or reference signal IRE(A) input option)
SD6 Digital input 6 * (factory setting: stop switch),
SD7 Option (Digital input 7 *, or feedback signal IRE(A) input)
SD8 Option (Digital input 8 *, or feedback signal IRE(B) input)
+24 V/D supply voltage output (max. 100 mA)
ST1
In case of PNP logic the common point of the digital inputs
GND/D (the reference point of the +24 V/D supply voltage output)
ST2
In case of NPN logic the common point of the digital inputs
CST Terminal serial line connector (CAN1 option)
CSR Option (System serial line and/or CAN2)
SR1
Digital output 1 ** (factory setting: ready - closing / error - opening)
SR2
SR3
Digital output 2 ** (factory setting: operate - closing / stop - opening)
SR4
SR5
Digital output 3 ** (factory setting: brake control) (optional for VLD 5,5 ÷ 11)
SR6
SR7 Digital output 3: In case of a relay contact closed in rest position (option)
* Switching level of the digital inputs: 0.6 to 2 mA
** Digital outputs: relay (max. 250 V AC / 1 A or 30 V DC / 0,5 A) or optocoupler (optional) (max. 30 V DC / 10 mA)
FREQUENCY CONVERTERS INSTRUCTION MANUAL
W
PE
R BRAKE
1K2
12V
12V
5
6
7
8
1
2
3
potentiometer (2÷10 kΩ), 0÷10 V (130 kΩ), 4÷20 mA (0÷20 mA) (100 Ω)
reference point (pl. GND/A)
potentiometer (2÷10 kΩ), 0÷10 V (130 kΩ), 4÷20mA (0÷20 mA) (100 Ω)
reference point (pl. GND/A)
3 x 400VAC
FAN
NPN
+24V/D
GND/D
PNP
SD
ST
4
5
6
1
2
(or reference signal IRE(B) input option)
(K1, K2, K3
(K1, K2, K3
- 13 -
3 x 400VAC
F1
F2
F3
L1
L2
L3
LINE
CST CSR
1
2
3
jumpers)
jumpers)
0,55 ÷ 200 kW
PE
SR
4
5
6
7

Advertisement

Table of Contents
loading

Table of Contents