Assignment And Connection Of The E3D Terminal Block - Procon E3D 0.55 Instruction Manual

Frequency converters 0,55 – 4 kw
Table of Contents

Advertisement

F
FREQUENCY CONVERTERS INSTRUCTION MANUAL
 ASSIGNMENT AND CONNECTION OF THE E3D TERMINAL BLOCK
Three-colour LED (green: On, yellow: Operate, red: Error, flashing yellow: Waiting)
SA1 +10V potentiometer driving output (max. 6 mA)
SA2 Analogue input 1 (reference signal): potentiometer (2÷10 kΩ), 0÷10 V, 4÷20 mA (0÷20 mA) *
SA3 GND (reference point of the inputs)
SA4 Analogue input 2 (feedback signal): 0÷10 V, 4÷20 mA (0÷20 mA) *
SD1 Digital input 1 (factory setting: start switch)
SD2 Digital input 2 (factory setting: reversing switch)
SD3 Digital input 3 (factory setting: error acknowledgement)
SD4 Digital input 4 (factory setting: external error)
SD5 +24V/D supply voltage output (max. 100 mA) (for digital inputs, remote transmitter)
ST1
Spare
ST2
SR1
Digital output 1 ** (factory setting: ready - closing / error - opening)
SR2
SR3
Option (Digital output 2 **) (factory setting: operate - closing / stop - opening)
SR4
* Current inputs (4÷20 mA, 0÷20 mA) have to be terminated with a 500 Ω resistor. (1 %, 0,5÷1 W)
** Digital outputs: relay (max. 250 V AC / 1 A or 30 V DC / 0,5 A) or optocoupler (optional) (max. 30 V DC / 10 mA)
M
~
U
V
W
PE
MOTOR
E3D frequency converter
SA
1
2
3
4
1
÷
2 10K
0÷10V
4÷ 0
2 mA
(0÷ 0
2 mA)
500Ω
min. 0,5W
remote transmitter
3 x 400VAC
F1
F2
L1
L2
R BRAKE
SD
ST
2
3
4 5
- 10 -
F3
L3
PE
LINE
SR
1
2
0,55 ÷ 4 kW

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3d 2.2E3d 1.1E3d 1.5E3d 3E3d 4E3d 0.75

Table of Contents