Grounding Procedure (For Flammable Materials Only); Pressure Relief Procedure - Graco LineLazer IV 250SPS Repair Manual

Self-propelled line striper
Hide thumbs Also See for LineLazer IV 250SPS:
Table of Contents

Advertisement

Grounding Procedure (For Flammable Materials Only)

Grounding Procedure
(For Flammable Materials Only)
This equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape
wire for the electric current.
1. Position striper so that the tires are not on pave-
ment.
2. Ground sprayer with grounding clamp. Grounding
clamp must attach to grounded object (e.g. metal
sign post).
10

Pressure Relief Procedure

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
1. Perform Grounding Procedure if using flammable
materials.
2. Set pump valve OFF. Turn engine OFF.
ti23146a
3. Turn pressure control to lowest setting. Trigger gun
to relieve pressure.
ti3441a
4. Engage gun trigger lock. Turn prime valve down.
Follow the Pressure Relief Procedure whenever
you see this symbol.
ti6740a
ti3324a
ti3305a
PAINT
ti6473a
3A2593C Repair

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents