Approved Standard Ratings
UL (File No. E41515), CSA (File No. LR45258)
Standard Load:
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Microload:
0.1 A at 125 VAC
0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
CCC (GB14048.5)
Standard Load:
0.5 A at 250 VAC
Microload:
0.1 A at 250 VAC
Ratings
Model
Item
AC resistive load
0.5 A at 250 VAC
Standard load
1 A at 125 VAC
Microload
*
0.1 A at 125 VAC
Note: The above ratings are for testing under the following conditions:
1) Load: Resistive load
2) Mounting conditions: No vibrations or shock
3) Temperature: 20°C ± 2°C
4) Operation frequency: 20 operations/minute
* The minimum permissible load is 1 mA, 5 VDC.
LED Lamp
Rated voltage
Rated current
5 VDC
30 mA
12 VDC
15 mA
24 VDC
10 mA
Incandescent Lamp
Rated voltage
Rated current
6 VAC/DC
60 mA
14 VAC/DC
40 mA
28 VAC/DC
24 mA
DC resistive load
1 A at 30 VDC
0.1 A at 30 VDC
Operating
Internal limiting
voltage
resistance
5 VDC ± 5%
33 Ω
12 VDC ± 5%
270 Ω
24 VDC ± 5%
1,600 Ω
Operating voltage
5 VAC/DC
12 VAC/DC
24 VAC/DC
Characteristics
Momentary-action models: 120 operations/minute max.
Operat-
Mechanical
Alternate-action models: 60 operations/minute max. *1
ing fre-
quency
Electrical
20 operations/minute max.
Standard load
50mΩ max.
Contact
Resis-
tance
Microload
100mΩ max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Between terminals
1,000 VAC, 50/60 Hz for 1 min
of same polarity
Between terminals
2,000 VAC, 50/60 Hz for 1 min
of different polarity
Dielectric
strength
Between each
2,000 VAC, 50/60 Hz for 1 min
terminal and ground
Between lamp
1,000 VAC, 50/60 Hz for 1 min *2
terminals
Vibration
resis-
Malfunction
10 to 55 Hz, 1.5-mm double amplitude *3
tance
Shock
Destruction
500 m/s
resis-
Malfunction
150 m/s
tance
Momentary-operation models: 1,000,000 operations min.
Mechanical
Alternate-operation models: 100,000 operations min. *1
Durability
Electrical
100,000 operations min.
Approx. 5 g <The weight indicated here applies
Weight
to the lighted models (SPST-NO+SPST-NC).>
−10°C to +55°C (with no icing or condensation)
Ambient operating temperature
Ambient operating humidity
35% to 85%RH
−25°C to +65°C (with no icing or condensation)
Ambient storage temperature
Degree of protection
IP40
Electric shock protection class
Class II
PTI (proof tracking index)
175
Pollution degree
3 (IEC60947-5-1)
*1. With alternate-operation models, one operation cycle consists of set and
reset operations.
*2. The figure given above for the dielectric strength between lamp terminals is
for when there is no LED lamp or incandescent lamp mounted.
*3. No malfunction for more than 1s.

Operating Characteristics

Operating force
OF max.
Releasing force
RF min.
Total travel
TT
Lock travel alternate LTA min.
*
Pretravel
PT max.
* Alternate operation models only.
Contact Form
Contact name
Contact form
NO
SPDT
NC
A3C
2
2
*3
2.45 N {250 gf}
0.29 N {30 gf}
Approx. 3.5 mm
0.5 mm
2.5 mm
NO
NC
8

Advertisement

Table of Contents
loading

Table of Contents