MAN B&W

Operation Panel for the Auxiliary Blowers

On the operation panel, three control modes are
available to run/stop the blowers:
• AUTO – Run/stop is automatically controlled by
scavenge air pressure
• MANUAL – Start of all blowers in sequence at
intervals of 6 sec
• OFF – The auxiliary blowers are stopped after a
set period of time, 30 sec for instance.
1,200mm wire harness,
shielded by 20mm jacket
Harness to be fixed to structure
Terminal row, to be mounted in
the Manoeuvring Console
Fig. 14.02.03: Control panel including operation panel, wiring harness and terminal row, option: 4 55 650
MAN B&W MC/MC-C, ME-B engines
The operation panel and terminal row have to be
mounted in the Engine Control Room Manoeu-
vring Console, see Section 16.01.
The control panel for the auxiliary blowers includ-
ing the operation panel, wiring harness and termi-
nal row is shown in Fig. 14.02.03.
MAIN ENGINE
AUXILIARY BLOWER CONTROL
AUXILIARY
AUXILIARY
BLOWER 1
BLOWER 2
RUNNING
RUNNING
AUXILIARY
AUXILIARY
BLOWER 4
BLOWER 5
RUNNING
RUNNING
AUTO
OFF
IN SERVICE
MAN Diesel
AUXILIARY
BLOWER 3
RUNNING
AUXILIARY
BLOWER 6
RUNNING
MANUAL
LAMP TEST
K5
K10
14.02
Page 3 of 3
K7
512 36 604.0.0
198 65 874.0