1 General information on parameterization
software
The parameterization masks are arranged in such a way that it is immediately
apparent to the user whether one-channel or two-channel signals are required to
achieve the necessary safety level.
For one-channel signals, the left side of the mask contains a terminal block
field in which block X3 or X4 can be selected. The required pin assignment can
also be entered.
For two-channel signals, terminals X3/X4 are automatically preassigned. The
only data that can be entered is the pin assignment. The pin assignment is
identical for blocks X3 and X4!
The entered value is saved by pressing the Accept button. A green dot appears to
the left if the entry has been saved properly and completely.