General functions
Multi-operator control
Multi-operator control (2-foot) is activated when operating mode 2 is selected
and foot switch 2 is not deactivated. In this case, if foot switch 2 is not
connected, a corresponding message is output and the valves cannot be
controlled (contact monitor).
Single operator control
Single operator control (foot) is activated when operating mode 2 is selected
and control element 2 is deactivated. In this case, if foot switch 2 is not
connected, a corresponding message is output and the valves cannot be
controlled (connection monitor).
Note
The connection monitor checks whether, for single operator control, all other
control elements (deactivated control elements) have been removed.
For multi-operator control, all activated control elements must be connected
(contact monitor).
If the monitoring function responds, messages are output to notify the user.
8.2 Single operator control via 2 foot switches and operating
error monitor
To implement single operator control via 2 separate foot switches, each foot switch
must be parameterized in a separate operating mode (e.g. foot switch 1 in
operating mode 2 and foot switch 2 in operating mode 3).
A complete stroke can be performed in operating mode 2 (foot switch 1).
Subsequently, the operating mode can be changed and a complete stroke can be
performed in operating mode 3 (foot switch 2). If operating mode 2 is active and
foot switch 2 was activated, a suitable message is output and the machine is
prevented from starting.
The system stops if a control element that was not selected is activated during a
press movement.
8-64
© Siemens AG 2003 All Rights Reserved
SIMOTION Safety Unit (AP) - Edition 06.2003