Figure 2-7
Figure 2-8
2.2.5

Automatic continuous stroke (operating mode 5)

Definition
This operating mode differs from the continuous mode in that two steps are
required to enable the machine for the first time:
First, the automatic continuous stroke mode is enabled using the two-hand
control.
Then the machine can be started by an external enable signal via the terminal.
Note
If at the time of the two-hand activation there is an external enable signal, the
machine starts immediately.
In this mode, the two-hand control acts as a command device only (not a
safety device). The operator must be protected by additional safety
equipment, e.g. ESPE!
© Siemens AG 2003 All Rights Reserved
SIMOTION Safety Unit (AP) - Edition 06.2003
Valve control of mechanical press (mechanical operation)
Valve control of hydraulic press (hydraulic operation)
Operating modes
2-17