2.5 Fixing System
2.5.1 Points to Note When
Mounting
the
Assembly
When fitting the fixing assembly into the fixing/
feeding assembly, take full care not to damage the 2
sensors [1].
[1]
F-2-40
2.5.2 After Replacing the
Fixing Roller
If you have replaced the fixing roller, be sure to
execute the following service mode item to reset the
counter reading:
COPIER>COUNTER>DRBL-1>FX-UP-RL
2.5.3 After Replacing the
Fixing Web
1. After attaching the web, take up its slack so that
there will be no slack when the web unit is fitted in the
fixing assembly.
2. After replacing the web, reset the readings of the
following service mode items:
COPIER>COUNTER>MISC>FIX-WEB
COPIER>COUNTER>DRBL-1>FX-WEB
Fixing
0004-1594
0004-5054
0004-1786
2.5.4 Position of the Fixing
inlet Guide
Do not loosen the screw on the inlet guide base
[1], as you would have to adjust the position of the
guide if you detached it. If you loosened it for some
reason, be sure to perform the following:
1) Adjust the position of the inlet guide base [1] so that
the height [A] at the center of the fixing inlet guide
[2] is 60.7 +/-0.2 mm and the difference in height
between the ribs [B] on both sides of the inlet guide
is 0.5 or less.
B
[2]
[1]
[1]
F-2-41
F-2-42
2.5.5 Points to Note When
Mounting the Pressure
Roller
Be sure to mount the pressure roller [1] so that the lot
number [2] found on its edge is found toward the front
of the machine.
Chapter 2
0004-2213
A
B
[1]
A
0005-8345
2-45