Chapter 4
4.4.1.4 E591; Scrap full detector sensor error
<Wiring>
1) Is the wiring between the scrap full detector PCB and the punch controller PCB normal?
NO : Repair the wiring.
<Scrap full detector PCB>
2) Does it improve when the scrap full detector PCB is replaced?
YES : End
NO : Replace the punch controller PCB.
<Punch controller PCB/Finisher controller PCB>
3) Does it improve when the punch controller PCB is replaced?
YES : End
NO : Replace the finisher controller PCB.
4.4.1.5 E592; Trailing edge/Horizontal registration sensor error
<Wiring>
1) Is the wiring between the LED PCB/photosensor PCB and the punch controller PCB normal?
NO : Repair the wiring.
<LED PCB/Photosensor PCB>
2) Does it improve when the LED PCB/photosensor PCB is replaced?
YES : End
NO : Replace the punch controller PCB.
<Punch controller PCB/Finisher controller PCB>
3) Does it improve when the punch controller PCB is replaced?
YES : End
NO : Replace the finisher controller PCB.
4.4.1.6 E593; Horizontal registration motor error
<Horizontal registration home position sensor (PI61)>
1) Check the horizontal registration home position sensor. Does the sensor operate normally?
NO : Replace the sensor.
<Wiring>
2) Is the wiring between the punch controller PCB and the sensor normal?
NO : Repair the wiring.
<Horizontal registration mechanism/ Horizontal registration motor (M62)>
3) Is there any abnormality in the horizontal registration mechanism?
YES : Repair the horizontal registration mechanism.
NO : Replace the horizontal registration motor.
<Punch controller PCB/Finisher controller PCB>
4) Does it improve when the punch controller PCB is replaced?
YES : End
NO : Replace the finisher controller PCB.
4-6
0003-8758
0003-8760